LU Fei, ZHANG Boni, QIN Yan, HU Tieli, YU Bing, SUN Yu’nan, CAO Feng. Optical chopper applied for calibration of vacuum ultraviolet detector[J]. Journal of Applied Optics, 2022, 43(2): 325-330. DOI: 10.5768/JAO202243.0204003
Citation: LU Fei, ZHANG Boni, QIN Yan, HU Tieli, YU Bing, SUN Yu’nan, CAO Feng. Optical chopper applied for calibration of vacuum ultraviolet detector[J]. Journal of Applied Optics, 2022, 43(2): 325-330. DOI: 10.5768/JAO202243.0204003

Optical chopper applied for calibration of vacuum ultraviolet detector

More Information
  • Received Date: October 26, 2021
  • Revised Date: December 24, 2021
  • Available Online: February 21, 2022
  • In order to precisely calibrate the absolute spectral responsivity of detector from 115 nm~400 nm based on cryogenic radiometer, an optical chopper used in vacuum was developed. The optical chopper consisted of blade, rotation axis, servo motor, U-shaped photoelectric switch, cooling module, bracket and controlling circuit could be used to modulate the weak vacuum ultraviolet-ultraviolet (VUV-UV) radiation signal to the alternating radiation signal which the frequency was known in vacuum cryogenic environment, and measured by lock-in amplifier. The experimental results show that the stability of the optical chopper is ±0.05 Hz at the frequency of 80 Hz, which meets the requirements of absolute spectral responsivity calibration of detector at 115 nm~400 nm in the vacuum environment of 10−4 Pa.

  • [1]
    翟保尊, 谷玉海, 王吉芳, 等. 精密光学斩波控制器设计[J]. 仪表技术与传感器,2016,41(3):24-27. doi: 10.3969/j.issn.1002-1841.2016.03.008

    ZHAI Baozun, GU Yuhai, WANG Jifang, et al. The controller design of the precision optical chopper[J]. Instrument Technique and Sensor,2016,41(3):24-27. doi: 10.3969/j.issn.1002-1841.2016.03.008
    [2]
    王欣. 垂面排列液晶盒光学导波的研究[D]. 天津: 河北工业大学, 2010.

    WANG Xin. Study of optical guided waves in the vertical alignment liquid crystal cell[D]. Tianjin: Hebei University of Technology, 2010.
    [3]
    邵英秋, 王言章, 程德福, 等. 基于磁反馈的宽频带磁传感器的研制[J]. 仪器仪表学报,2010,31(11):2461-2466.

    SHAO Yingqiu, WANG Yanzhang, CHENG Defu, et al. Development of wide-band magnetic sensors based on magnetic feedback[J]. Chinese Journal of Scientific Instrument,2010,31(11):2461-2466.
    [4]
    WITTE J F, HUIJSING J H, MAKINWA K. A current feedback instrumentation amplifier with 5 V offset for bidirectional high-side current-sensing[J]. IEEE Journal of Solid-State Circuits,2008,43(12):2769-2775. doi: 10.1109/JSSC.2008.2005695
    [5]
    PERTIJS M A P, KINDT W J. A 140 dB-CMRR current feedback instrumentation amplifier employing ping-pong auto-zeroing and chopping[J]. IEEE Journal of Solid-State Circuits,2010,45(10):2044-2056. doi: 10.1109/JSSC.2010.2060253
    [6]
    BURT R, ZHANG J. A micropower chopper-stabilized operational amplifier using a SC notch filter with synchronous integration inside the continuous-time signal path[J]. IEEE Journal of Solid-State Circuits,2006,41(12):2729-2736. doi: 10.1109/JSSC.2006.884195
    [7]
    HARRISON R R, CHARLES C. A low-power low-noise CMOS amplifier for neural recording applications[J]. IEEE Journal of Solid-State Circuits,2003,38(6):958-965. doi: 10.1109/JSSC.2003.811979
    [8]
    ENZ C C, TEMES G C. Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilization[J]. IEEE,2002,84(11):1584-1614.
    [9]
    吕扬. 日盲滤光片高精度透过率测试系统研制[D]. 南京: 南京理工大学, 2016.

    LYU Yang. Development of high-precision transmittance test system for sun blind filters[D]. Nanjing: Nanjing University of Science and Technology, 2016.
    [10]
    王骥, 郑小兵, 张磊, 等. 一种近红外探测器的光谱响应率测量[J]. 应用光学,2007,28(3):313-316. doi: 10.3969/j.issn.1002-2082.2007.03.016

    WANG Ji, ZHENG Xiaobing, ZHANG Lei, et al. Measurement of spectral responsivity of an infrared detector[J]. Journal of Applied Optics,2007,28(3):313-316. doi: 10.3969/j.issn.1002-2082.2007.03.016
    [11]
    张辉, 刘建伟, 杨良, 等. 紫外及可见探测器光谱响应测试系统的研制[J]. 激光与红外,2003,33(5):371-373. doi: 10.3969/j.issn.1001-5078.2003.05.016

    ZHANG Hui, LIU Jianwei, YANG Liang, et al. Development of spectral responsivity testing system for ultraviolet and visible detectors[J]. Laser and Infrared,2003,33(5):371-373. doi: 10.3969/j.issn.1001-5078.2003.05.016
    [12]
    崔丽, 叶先明. 基于 AVR 单片机的直流无刷电机智能控制系统设计[J]. 仪表技术与传感器,2009(11):34-36. doi: 10.3969/j.issn.1002-1841.2009.11.012

    CUI Li, YE Xianming. Design of BLDCM intelligent control system based on AVR single-chip microcomputer[J]. Instrument Technique and Sensor,2009(11):34-36. doi: 10.3969/j.issn.1002-1841.2009.11.012
    [13]
    曹金良, 贾雪艳. 基于DSP控制的斩波器无刷直流电动机调压调速系统的设计[J]. 内蒙古石油化工,2010,36(4):63-64. doi: 10.3969/j.issn.1006-7981.2010.04.026

    CAO Jinliang, JIA Xueyan. Design of the chopper brushless DC motor speed regulator system based on the control of: DSP[J]. Inner Mongolia Petrochemical,2010,36(4):63-64. doi: 10.3969/j.issn.1006-7981.2010.04.026
    [14]
    孙亚隆. 永磁同步电机热管式散热系统设计与性能分析[D]. 广州: 华南理工大学, 2019.

    SUN Yalong. Design and performance analysis of heat pipe based cooling system for permanent magnet synchronous motors[D]. Guangzhou: South China University of Technology, 2019.
    [15]
    尹惠. 永磁同步电机损耗计算及温度场分析[D]. 哈尔滨: 哈尔滨工业大学, 2015.

    YIN Hui. PMSM loss calculation and temperature field analysis[D]. Harbin: Harbin Institute of Technology, 2015.
  • Related Articles

    [1]LI Yan, FAN Jihong, YU Bing, YUAN Lin'guang, SUN Yu'nan, QIN Yan, MA Li. Spectral responsivity measurement technology for UV detector based on cryogenic radiometer[J]. Journal of Applied Optics, 2022, 43(2): 311-316. DOI: 10.5768/JAO202243.0204001
    [2]LIN Yongjie, XU Nan, HE Yingwei, LIU Wende, GAN Haiyong, GONG Huaping. Relative spectral responsivity calibration technology of InGaAs photodetector based on super-continuum light source[J]. Journal of Applied Optics, 2021, 42(4): 709-716. DOI: 10.5768/JAO202142.0403003
    [3]Zhang Yan-na, Zheng Xiao-bing, Li Xin, Wei Wei, Pang Wei-wei. Calibrating method traced to cryogenic absolute radiometer for solar irradiance spectroradiometer[J]. Journal of Applied Optics, 2015, 36(4): 572-579. DOI: 10.5768/JAO201536.0403003
    [4]TAO Kun-yu, LI Fu-wei, FU Sen, ZHOU Yan-ping. Error analysis and comparison of spectral responsivity calibration methods for HgCdTe-IRFPA imaging detector[J]. Journal of Applied Optics, 2007, 28(5): 587-592.
    [5]WANG Ji, ZHENG Xiao-bing, ZHANG Lei, LIN Zhi-qiang. Measurement of spectral responsivity of an infrared detector[J]. Journal of Applied Optics, 2007, 28(3): 313-316.
    [6]CHENG Hong-chang, SHENG Liang, SHI Feng, WANG Fen-fen, FENG Liu. Spectral response measurement of UV image intensifier[J]. Journal of Applied Optics, 2007, 28(3): 305-308.
    [7]FAN Ji-hong, HOU Xi-qi, YANG Zhao-jin, YIN Tao, QIN Yan, LIU Jian-ping. Measurement technology for spectral responsivity of infrared detector[J]. Journal of Applied Optics, 2006, 27(5): 460-462.
    [8]FAN Ji-hong, YANG Zhao-jin, QIN Yan. Research of test technology for absolute spectral responsivity of HgCdTe detector[J]. Journal of Applied Optics, 2006, 27(supp): 79-82.
    [9]SHI Ji-fang, HOU Xi-qi, FAN Ji-hong, SUN Yu-nan. Study of spectral responsivity testing technologyfor photocathodes of image intensifiers[J]. Journal of Applied Optics, 2006, 27(supp): 68-70.
    [10]ZHAN Chun-lian, LI Yan-mei, LIU Jian-ping, LI Zheng-qi. The Unitormity and Linearity of Infrared Spectral Response of Decector[J]. Journal of Applied Optics, 2004, 25(6): 34-37.
  • Cited by

    Periodical cited type(1)

    1. 杜振中. 基于机器视觉的运动误差自动校正系统设计. 现代电子技术. 2019(19): 107-111 .

    Other cited types(0)

Catalog

    Article views (376) PDF downloads (46) Cited by(1)

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return