FAN Ji-hong, HOU Xi-qi, YANG Zhao-jin, YIN Tao, QIN Yan, LIU Jian-ping. Measurement technology for spectral responsivity of infrared detector[J]. Journal of Applied Optics, 2006, 27(5): 460-462.
Citation: FAN Ji-hong, HOU Xi-qi, YANG Zhao-jin, YIN Tao, QIN Yan, LIU Jian-ping. Measurement technology for spectral responsivity of infrared detector[J]. Journal of Applied Optics, 2006, 27(5): 460-462.

Measurement technology for spectral responsivity of infrared detector

More Information
  • Corresponding author:

    FAN Ji-hong

  • The spectral responsivity is one of the important parameters of detector. With the development of infrared detect technique, accurate measurement for the spectral responsivity of infrared detector becomes more and more important. The technique on how to measure the spectral responsivity of infrared detector is introduced. Based on an infrared spectral responsivity facility in the institute,the cavity pyroelectric detector is used to calibrate the relative spectral responsivity of infrared detector in several wavelengths on the facility. After repeated measurement,different results are achieved and their average is given in the paper. At last the uncertainty which influences the results is analyzed. Since the wavelength range of infrared spectral responsivity facility is 1~20μm, the relative spectral responsivity of InSb detector and HgCdTe detector can also be measured. The analysis of the uncertainty shows that the measurement accuracy of the spectral responsivity of infrared detector meets the requirement.
  • Related Articles

    [1]ZHANG Yuetong, CHEN Wenliang, WANG Xiangjun, LIU Feng, WANG Meiyi. FDM printing trajectory measurement and quality evaluation method based on infrared imaging[J]. Journal of Applied Optics, 2024, 45(5): 1008-1018. DOI: 10.5768/JAO202445.0503003
    [2]WANG Xueqi, HE Zehao, ZHU Qiaofen, CAO Liangcai. Image quality evaluation method and system for head-mounted three-dimensional display[J]. Journal of Applied Optics, 2024, 45(3): 598-607. DOI: 10.5768/JAO202445.0301002
    [3]ZHAO Yonggang, SUN Chunsheng. Light source calibration for divided focal plane polarization imaging system[J]. Journal of Applied Optics, 2022, 43(5): 967-972. DOI: 10.5768/JAO202243.0503006
    [4]WANG Huilin, LIU Jilong, WU Xiongxiong, LUAN Yadong. Image quality influencing factors for aerial electro-optical detection[J]. Journal of Applied Optics, 2021, 42(5): 817-829. DOI: 10.5768/JAO202142.0502001
    [5]Wang Fan, Ni Jinping, Dong Tao, Guo Rongli. No-reference image quality assessment method based on visual attention mechanism and sharpness metric approach[J]. Journal of Applied Optics, 2018, 39(1): 51-56. DOI: 10.5768/JAO201839.0101009
    [6]Wu Haibing, Tao Shengxiang, Zhang Liang, Zhang Jing. Tricolor acquisition and true color images fusion method under low illumination condition[J]. Journal of Applied Optics, 2016, 37(5): 673-679. DOI: 10.5768/JAO201637.0502001
    [7]an Le-le, Li Hui, Qiu Ju-neng, Liang Ping. Image quality assessment method based on regional contrast and structural similarity[J]. Journal of Applied Optics, 2015, 36(1): 58-63. DOI: 10.5768/JAO201536.0102002
    [8]Guo Lian-peng, Chen Xiang-ning, Liu Bin, Liu Tian-jian. 3D-object reconstruction based on fusion of depth images by Kinect sensor[J]. Journal of Applied Optics, 2014, 35(5): 811-816.
    [9]FAN Yuan-yuan, SANG Ying-jun, SHEN Xiang-heng. No-reference image SNR assessment under visual masking[J]. Journal of Applied Optics, 2012, 33(4): 711-716.
    [10]FAN Yuan-yuan, SANG Ying-jun, SHEN Xiang-heng. Optimization of image quality assessment parameters based on back-propagation neural network[J]. Journal of Applied Optics, 2011, 32(6): 1150-1155.

Catalog

    Article views (4248) PDF downloads (2062) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return