WANG Shengyun, XIE Qi, SHI Jifang, SUN Yunan, YU Bing, KANG Dengkui. Measurement system of radiation sensitivity for UV image intensifier[J]. Journal of Applied Optics, 2020, 41(3): 548-552. DOI: 10.5768/JAO202041.0303001
Citation: WANG Shengyun, XIE Qi, SHI Jifang, SUN Yunan, YU Bing, KANG Dengkui. Measurement system of radiation sensitivity for UV image intensifier[J]. Journal of Applied Optics, 2020, 41(3): 548-552. DOI: 10.5768/JAO202041.0303001

Measurement system of radiation sensitivity for UV image intensifier

More Information
  • Received Date: October 29, 2019
  • Revised Date: March 20, 2020
  • Available Online: May 29, 2020
  • The ultraviolet (UV) image intensifier is the core device of the UV detection system, which is a kind of electric vacuum imaging device, and can transform and enhance the weak UV images into the optical images that can be detected by eyes. The development and application of the UV image intensifier is an important orientation of the low-light-level night vision technology. The radiant sensitivity is a key parameter to evaluate the UV image intensifier, which directly determines the performance of the UV detection system. The measuring principle of the radiant sensitivity for UV image intensifier was introduced, and the measuring system was constructed by the UV radiation source, grating monochromator system, testing dark box, micro galvanometer, computer and measuring software. The radiant sensitivity of three UV image intensifier at wavelengths of 260 nm, 280 nm and 320 nm was measured, respectively, and the measurement uncertainty was analyzed. The spectral range of the radiant sensitivity measuring system is extended to 200 nm~400 nm by the establishment of the measuring system, which makes up for the deficiency of the existing system and has broad application prospects.
  • [1]
    WILCOX P G, SAFRONOVA A S, KANTSYREV V L, et al. Extreme ultraviolet spectroscopy of low-Z ion plasmas for fusion applications[J]. Review of Scientific Instruments,2008,79(10):10F543. doi: 10.1063/1.2956745
    [2]
    SOUKHANOVSKII V A, STUTMAN D, FINKENTHAL M, et al. Compact collimated vacuum ultraviolet diagnostics for localized impurity measurements in fusion boundary plasmas[J]. Review of Scientific Instruments,2001,72(8):3270-3276. doi: 10.1063/1.1386906
    [3]
    杨杰. 紫外探测技术的应用与进展[J]. 光电子技术,2011,31(4):274-278. doi: 10.3969/j.issn.1005-488X.2011.04.012

    YANG Jie. The application and development of UV detection technology[J]. Optoelectronic Technology,2011,31(4):274-278. doi: 10.3969/j.issn.1005-488X.2011.04.012
    [4]
    滕鹤松. 紫外成像技术及其应用[J]. 光电子技术,2001,21(4):294-297. doi: 10.3969/j.issn.1005-488X.2001.04.010

    TENG Hesong. UV imaging technology and its applications[J]. Optoelectronic Technology,2001,21(4):294-297. doi: 10.3969/j.issn.1005-488X.2001.04.010
    [5]
    吴星琳, 邱亚峰, 钱芸生, 等. 紫外像增强器信噪比与MCP电压的关系[J]. 应用光学,2013,34(3):494-497.

    WU Xinglin, QIU Yafeng, QIAN Yunsheng, et al. Relationship between voltage of MCP and signal-to-noise ratio of UV image intensifier[J]. Journal of Applied Optics,2013,34(3):494-497.
    [6]
    宋亚军, 韩放. “日盲”紫外成像技术分析及应用展望[J]. 航天电子对抗,2019,35(1):53-60. doi: 10.3969/j.issn.1673-2421.2019.01.013

    SONG Yajun, HAN Fang. Analysis and application of solar blind ultraviolet imaging technology[J]. Aerospace Electronic Warfare,2019,35(1):53-60. doi: 10.3969/j.issn.1673-2421.2019.01.013
    [7]
    程宏昌, 端木庆铎, 石峰, 等. 双微通道板紫外像增强器工作特性研究[J]. 真空科学与技术学报,2013,33(6):524-527. doi: 10.3969/j.issn.1672-7126.2013.06.04

    CHENG Hongchang, DUANMU Qingduo, SHI Feng, et al. Characterization of solar blind double micro-channel plate ultraviolet image intensifier[J]. Chinese Journal of Vacuum Science and Technology,2013,33(6):524-527. doi: 10.3969/j.issn.1672-7126.2013.06.04
    [8]
    李想, 王恒茂, 曹汛, 等. 日盲紫外探测技术在空间预警中的应用[J]. 航天返回与遥感,2014,35(4):1-8. doi: 10.3969/j.issn.1009-8518.2014.04.001

    LI Xiang, WANG Hengmao, CAO Xun, et al. Application of solar blind UV detection technology in space warning[J]. Spacecraft Recovery and Remote Sensing,2014,35(4):1-8. doi: 10.3969/j.issn.1009-8518.2014.04.001
    [9]
    杨承, 曾钦勇, 朱大勇, 等. 日盲型紫外探测系统的探测距离模型及实验研究[J]. 光电工程,2010,37(9):133-139. doi: 10.3969/j.issn.1003-501X.2010.09.023

    YANG Cheng, ZENG Qinyong, ZHU Dayong, et al. Theoretical and experimental study on detection range model of solar blind ultraviolet detection system[J]. Opto-Electronic Engineering,2010,37(9):133-139. doi: 10.3969/j.issn.1003-501X.2010.09.023
    [10]
    张宣妮, 王益军, 张玉叶. 紫外探测技术的新发展[J]. 价值工程,2010,29(17):3-5. doi: 10.3969/j.issn.1006-4311.2010.17.002

    ZHANG Xuanni, WANG Yijun, ZHANG Yuye. New developments of UV-detection technology[J]. Value Engineering,2010,29(17):3-5. doi: 10.3969/j.issn.1006-4311.2010.17.002
    [11]
    张振中, 李其祥. 微光夜视技术的发展及评价[J]. 山西科技,2007,22(3):110-111. doi: 10.3969/j.issn.1004-6429.2007.03.056

    ZHANG Zhenzhong, LI Qixiang. Development of low light night vision technology and appraisals[J]. Shanxi Science and Technology,2007,22(3):110-111. doi: 10.3969/j.issn.1004-6429.2007.03.056
    [12]
    陈雪, 李宗轩, 闫丰, 等. 日盲紫外像增强器绝对光谱响应测试系统[J]. 光电工程,2016,43(5):8-14. doi: 10.3969/j.issn.1003-501X.2016.05.002

    CHEN Xue, LI Zongxuan, YAN Feng, et al. Test system for absolute spectral response of SBUV image intensifier[J]. Opto-Electronic Engineering,2016,43(5):8-14. doi: 10.3969/j.issn.1003-501X.2016.05.002
    [13]
    付利平, 王咏梅, 陶冶, 等. 远紫外像增强器光谱响应特性研究[J]. 光谱学与光谱分析,2009,29(5):1375-1377. doi: 10.3964/j.issn.1000-0593(2009)05-1375-03

    FU Liping, WANG Yongmei, TAO Ye, et al. Spectral response measurement of FUV image intensifier[J]. Spectroscopy and Spectral Analysis,2009,29(5):1375-1377. doi: 10.3964/j.issn.1000-0593(2009)05-1375-03
    [14]
    贺英萍, 尹雷, 拜晓锋, 等. 紫外像增强器辐射增益测试方法研究[J]. 真空电子技术,2013,302(1):56-58. doi: 10.3969/j.issn.1002-8935.2013.01.011

    HE Yingping, YIN Lei, BAI Xiaofeng, et al. Testing method of radiation gain about UV image intensifier[J]. Vacuum Electronics,2013,302(1):56-58. doi: 10.3969/j.issn.1002-8935.2013.01.011
    [15]
    刘涛, 邱亚峰. 紫外像增强器辐射增益测试系统设计[J]. 应用光学,2015,36(5):723-727. doi: 10.5768/JAO201536.0501010

    LIU Tao, QIU Yafeng. Testing system of radiation gain in UV image intensifiers[J]. Journal of Applied Optics,2015,36(5):723-727. doi: 10.5768/JAO201536.0501010
    [16]
    程宏昌, 盛亮, 石峰, 等. 紫外像增强器光谱响应特性测量方法研究[J]. 应用光学,2007,28(3):305-308.

    CHENG Hongchang, SHENG Liang, SHI Feng, et al. Spectral response measurement of UV image intensifier[J]. Journal of Applied Optics,2007,28(3):305-308.
  • Related Articles

    [1]LI Yan, FAN Jihong, YU Bing, YUAN Lin'guang, SUN Yu'nan, QIN Yan, MA Li. Spectral responsivity measurement technology for UV detector based on cryogenic radiometer[J]. Journal of Applied Optics, 2022, 43(2): 311-316. DOI: 10.5768/JAO202243.0204001
    [2]LIN Yongjie, XU Nan, HE Yingwei, LIU Wende, GAN Haiyong, GONG Huaping. Relative spectral responsivity calibration technology of InGaAs photodetector based on super-continuum light source[J]. Journal of Applied Optics, 2021, 42(4): 709-716. DOI: 10.5768/JAO202142.0403003
    [3]Zhang Yan-na, Zheng Xiao-bing, Li Xin, Wei Wei, Pang Wei-wei. Calibrating method traced to cryogenic absolute radiometer for solar irradiance spectroradiometer[J]. Journal of Applied Optics, 2015, 36(4): 572-579. DOI: 10.5768/JAO201536.0403003
    [4]TAO Kun-yu, LI Fu-wei, FU Sen, ZHOU Yan-ping. Error analysis and comparison of spectral responsivity calibration methods for HgCdTe-IRFPA imaging detector[J]. Journal of Applied Optics, 2007, 28(5): 587-592.
    [5]WANG Ji, ZHENG Xiao-bing, ZHANG Lei, LIN Zhi-qiang. Measurement of spectral responsivity of an infrared detector[J]. Journal of Applied Optics, 2007, 28(3): 313-316.
    [6]CHENG Hong-chang, SHENG Liang, SHI Feng, WANG Fen-fen, FENG Liu. Spectral response measurement of UV image intensifier[J]. Journal of Applied Optics, 2007, 28(3): 305-308.
    [7]FAN Ji-hong, HOU Xi-qi, YANG Zhao-jin, YIN Tao, QIN Yan, LIU Jian-ping. Measurement technology for spectral responsivity of infrared detector[J]. Journal of Applied Optics, 2006, 27(5): 460-462.
    [8]FAN Ji-hong, YANG Zhao-jin, QIN Yan. Research of test technology for absolute spectral responsivity of HgCdTe detector[J]. Journal of Applied Optics, 2006, 27(supp): 79-82.
    [9]SHI Ji-fang, HOU Xi-qi, FAN Ji-hong, SUN Yu-nan. Study of spectral responsivity testing technologyfor photocathodes of image intensifiers[J]. Journal of Applied Optics, 2006, 27(supp): 68-70.
    [10]ZHAN Chun-lian, LI Yan-mei, LIU Jian-ping, LI Zheng-qi. The Unitormity and Linearity of Infrared Spectral Response of Decector[J]. Journal of Applied Optics, 2004, 25(6): 34-37.
  • Cited by

    Periodical cited type(1)

    1. 杜振中. 基于机器视觉的运动误差自动校正系统设计. 现代电子技术. 2019(19): 107-111 .

    Other cited types(0)

Catalog

    Article views (1566) PDF downloads (49) Cited by(1)

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return