WANG Ying-li, DAI Jing-min, ZHANG Xiao-qing, SUN Xiao-gang. Testing and analysis for total obscure power of phosphorus-derived smoke[J]. Journal of Applied Optics, 2007, 28(6): 797-801.
Citation: WANG Ying-li, DAI Jing-min, ZHANG Xiao-qing, SUN Xiao-gang. Testing and analysis for total obscure power of phosphorus-derived smoke[J]. Journal of Applied Optics, 2007, 28(6): 797-801.

Testing and analysis for total obscure power of phosphorus-derived smoke

More Information
  • Corresponding author:

    WANG Ying-li

  • In the field of smoke screen technology, the total obscure power (TOP) is a characterization parameter of smokescreen obscure power for human visual. A smokescreen TOP testing system, which can implement the automatic TOP measurement, was developed based on the irradiance measurement technology. This system is stable, efficient, real-time and reconfigurable. Under the conditions of 26℃ and 80% relative humidity, a test for yellow phosphorus-derived smoke TOP was performed. It was verified that the test result conformed with the empirical value.
  • Related Articles

    [1]Liu Qi, Chen Shanyong. Multi wavelength displacement interferometry based on square wave phase modulation[J]. Journal of Applied Optics.
    [2]ZHANG Qianchuang, GUO Chenxia, YANG Ruifeng, CHEN Xiaole. Super-resolution reconstruction of fiber optic coil image based on lightweight network[J]. Journal of Applied Optics, 2022, 43(5): 913-920. DOI: 10.5768/JAO202243.0502005
    [3]CHEN Yufang, WU Zhencong, WANG Min. Design and application of optical system for high-resolution micro space-borne camera[J]. Journal of Applied Optics, 2020, 41(2): 235-241. DOI: 10.5768/JAO202041.0201001
    [4]Zhai Yusheng, Jiang Liujie, Wang Xinjie, Zhang Zhifeng, Liu Jiaming. High-precision displacement measurement method based on laser modulation[J]. Journal of Applied Optics, 2018, 39(2): 230-234. DOI: 10.5768/JAO201839.0203004
    [5]Ma Chen-hao, Fu Yue-gang. Method for increasing HWS sampling rate on lens micro-scanning[J]. Journal of Applied Optics, 2015, 36(5): 768-773. DOI: 10.5768/JAO201536.0503001
    [6]YAN Hai-tao, MENG Wei-dong, ZHAO Xiao-yan, ZHEN Zhi-qiang. Micro-displacement measurement based on comparison of interference fringe[J]. Journal of Applied Optics, 2012, 33(6): 1069-1072.
    [7]ZHOU Geng-xia, BAN Shu-bao, SUN Tian-yu, GU Ji-hua, WU Dong-min. Resolution of micro-stereo-lithography system using high viscosity nanocomposites[J]. Journal of Applied Optics, 2011, 32(5): 867-871.
    [8]ZHU Ji-zhong, CHEN Ruo-lei, LU Zhong. Low-voltage micro-displacement driving circuit and its control method[J]. Journal of Applied Optics, 2007, 28(3): 354-357.
    [9]ZHANG Dong-ling, HE Feng-tao, FENG Xiao-qiang, HOU Xun. Highresolution Optical MicroSurvey System with Blue Illuminating Source[J]. Journal of Applied Optics, 2005, 26(3): 57-59.
    [10]ZHANG Wen-tao, ZHU Bao-hua. The Analysis and Study of Multiple-sampling of CCD in the APT Technology of Optical[J]. Journal of Applied Optics, 2004, 25(6): 9-11.