LU Hai, LI Ruo-ping, SUN Cai-xia, HUANG Ming-ju. Theoretical fitting of photochemical reaction parameters in holographic photopolymer[J]. Journal of Applied Optics, 2008, 29(2): 307-312.
Citation: LU Hai, LI Ruo-ping, SUN Cai-xia, HUANG Ming-ju. Theoretical fitting of photochemical reaction parameters in holographic photopolymer[J]. Journal of Applied Optics, 2008, 29(2): 307-312.

Theoretical fitting of photochemical reaction parameters in holographic photopolymer

More Information
  • Corresponding author:

    LU Hai

  • The transmittance curves of the photopolymer which sensitized by different dual-dyes were fitted based on the basic photochemical reaction process of the photopolymer and its theoretical function model, and the parameters in the theoretical model of the photochemical reaction were obtained. A new method to realize the curve fitting by MATLAB and obtain the photomechanical parameters in the photopolymer, based on the theoretical model and experimental data, was analyzed. The analysis shows that the R-Square of fitting statistics for three photopolymers are 0.9687,0.9958 and 0.9902 respectively when the exposure wavelength is 633nm and the exposure intensity is 65mW/cm2. It means that the fitting method is successful.
  • Related Articles

    [1]LI Yan, FAN Jihong, YU Bing, YUAN Lin'guang, SUN Yu'nan, QIN Yan, MA Li. Spectral responsivity measurement technology for UV detector based on cryogenic radiometer[J]. Journal of Applied Optics, 2022, 43(2): 311-316. DOI: 10.5768/JAO202243.0204001
    [2]WANG Shengyun, XIE Qi, SHI Jifang, SUN Yunan, YU Bing, KANG Dengkui. Measurement system of radiation sensitivity for UV image intensifier[J]. Journal of Applied Optics, 2020, 41(3): 548-552. DOI: 10.5768/JAO202041.0303001
    [3]CAO Xi-bin, ZHAO Bao-sheng, SAI Xiao-feng, WEI Yong-lin, ZHU Xiang-ping, ZHOU Wei, WANG Jun-feng, DONG Gai-yun. Ultraviolet image intensifier with response at 120 nm~200 nm[J]. Journal of Applied Optics, 2008, 29(5): 731-734.
    [4]XIANG Shi-ming. Theoretical limit for photocathode sensitivityof image intensifier[J]. Journal of Applied Optics, 2008, 29(1): 48-51.
    [5]TAO Kun-yu, LI Fu-wei, FU Sen, ZHOU Yan-ping. Error analysis and comparison of spectral responsivity calibration methods for HgCdTe-IRFPA imaging detector[J]. Journal of Applied Optics, 2007, 28(5): 587-592.
    [6]WANG Ji, ZHENG Xiao-bing, ZHANG Lei, LIN Zhi-qiang. Measurement of spectral responsivity of an infrared detector[J]. Journal of Applied Optics, 2007, 28(3): 313-316.
    [7]FAN Ji-hong, HOU Xi-qi, YANG Zhao-jin, YIN Tao, QIN Yan, LIU Jian-ping. Measurement technology for spectral responsivity of infrared detector[J]. Journal of Applied Optics, 2006, 27(5): 460-462.
    [8]FAN Ji-hong, YANG Zhao-jin, QIN Yan. Research of test technology for absolute spectral responsivity of HgCdTe detector[J]. Journal of Applied Optics, 2006, 27(supp): 79-82.
    [9]SHI Ji-fang, HOU Xi-qi, FAN Ji-hong, SUN Yu-nan. Study of spectral responsivity testing technologyfor photocathodes of image intensifiers[J]. Journal of Applied Optics, 2006, 27(supp): 68-70.
    [10]ZHAN Chun-lian, LI Yan-mei, LIU Jian-ping, LI Zheng-qi. The Unitormity and Linearity of Infrared Spectral Response of Decector[J]. Journal of Applied Optics, 2004, 25(6): 34-37.