XU Li-sheng, CHEN Wei, LI Jian-zhong, HU Fang-long. Application of photomultiplier tube in detection of cement grout density[J]. Journal of Applied Optics, 2007, 28(1): 102-104.
Citation: XU Li-sheng, CHEN Wei, LI Jian-zhong, HU Fang-long. Application of photomultiplier tube in detection of cement grout density[J]. Journal of Applied Optics, 2007, 28(1): 102-104.

Application of photomultiplier tube in detection of cement grout density

More Information
  • Corresponding author:

    CHEN Wei

  • In order to monitor the cement grout density accurately and dynamically in grouting practice, a detection instrument incorporating a CR105 photomultiplier tube as optic sensor was designed. The instrument, which took Cs-137 as light source, CR105 photomultiplier tube as photosensitive device and 196KB single chip processor as micro-processor, realized γ ray detection and data processing through the customized signal process circuit, display circuit and modularized software. The experimental results show that the instrument can successfully monitor the density of the cement grout in harsh environment. The detector of the instrument functions properly when it is installed in the hot, damp and dusty construction site. The measurement is fast and accurate.
  • Related Articles

    [1]SU Chengzhi, YAN Chun, WANG Fei, ZHANG Chengshuang, BAO Yanling, RUAN Yingbo. Research on error compensation method for infrared temperature measurement under laser irradiation[J]. Journal of Applied Optics, 2019, 40(6): 1084-1090. DOI: 10.5768/JAO201940.0603001
    [2]Jia Zhenan, Duan Weiwei, Liu Yinggang, Zhang Jingle, Li Kang. Tapered multi-mode fiber temperature sensor based on simultaneous response of wavelength and intensity[J]. Journal of Applied Optics, 2017, 38(2): 331-335. DOI: 10.5768/JAO201738.0208001
    [3]Xue Zhanli, Yuan Linguang, Wu Pei, Chen Juan. Study on low-temperature infrared radiator[J]. Journal of Applied Optics, 2016, 37(4): 623-627. DOI: 10.5768/JAO201637.0406002
    [4]WU Zhi-feng, DAI Cai-hong, YU Jia-lin, HUANG Bo, OUYANG Hui-quan. Performance investigation of blackbody BB3 500 M and temperature measurement[J]. Journal of Applied Optics, 2012, 33(5): 926-930.
    [5]YE Lu. Temperature stability analysis of static angle calibration devices[J]. Journal of Applied Optics, 2012, 33(2): 333-336.
    [6]CHEN Wei. Design of polymer parallel double-ring temperature sensor[J]. Journal of Applied Optics, 2010, 31(3): 495-498.
    [7]QIU Ya-feng, CHANG Ben-kang, QIAN Yun-sheng, GAO You-tang, TIAN Si. Heat uniformity analysis and design of filament of area source electron gun[J]. Journal of Applied Optics, 2007, 28(3): 265-268.
    [8]WANG Bao-zhu, ZHAO Sheng-lu, CHEN Wei, DENG Hong-lin. Temperature adaptability test and evaluation for optical fiber transmission performance[J]. Journal of Applied Optics, 2006, 27(6): 588-593.
    [9]WANG Lei, YANG Zhao-jin, LI Gao-ping, ZONG Ya-kang. An Equipment for Measuring the Temperature Coefficient of Refractive Index of Infrared Materials[J]. Journal of Applied Optics, 2005, 26(3): 54-56.
    [10]ZHU Shao-li, LIU De-sen, WU Jian-wei, XU Qiu-shuang. The Temperature Character of a Novel Variable Optical Attenuator[J]. Journal of Applied Optics, 2005, 26(1): 63-64.

Catalog

    Article views (2817) PDF downloads (1030) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return