CHENG Wang-bin, HUANG Ying. Indoor formaldehyde concentration detection with spectroscopic analysis[J]. Journal of Applied Optics, 2007, 28(1): 105-108.
Citation: CHENG Wang-bin, HUANG Ying. Indoor formaldehyde concentration detection with spectroscopic analysis[J]. Journal of Applied Optics, 2007, 28(1): 105-108.

Indoor formaldehyde concentration detection with spectroscopic analysis

More Information
  • Corresponding author:

    CHENG Wang-bin

  • A grating spectrum detecting system was designed to detect the formaldehyde concentration effectively and quickly. The spectrum detecting system mainly consists of optical system, signal collection system and computer processing system. The hardware circuits of the whole system include the driving circuit of the photoelectric magnification tube, preamplified filtering circuit, analogy and digital conversion circuit, and data collection and transmission circuit. The experiment conditions for determination of formaldehyde concentration in the air detected by MBTH spectrophotometer are investigated. The factors affecting experiment results are analyzed,experimental results for spectrum detection are obtained, the relevant conclusions are analyzed and reviewed. The transmission spectrum of the formaldehyde analytical solution,in which the formaldehyde concentration is fixed, can be correctly probed by the designed weak-light detection system.
  • Related Articles

    [1]ZHANG Jing, SUN Wenhan, FU Xiuhua, PAN Yonggang, WANG Ben, LIN Zhaowen, SHI Peng. Research on infrared ultrawideband beam splitter[J]. Journal of Applied Optics, 2024, 45(6): 1270-1276. DOI: 10.5768/JAO202445.0605001
    [2]LIU Xinyan, QIAN Yunsheng, WEI Jingwen. Automatic test system for progressive gain of dynode photomultiplier tube[J]. Journal of Applied Optics, 2022, 43(6): 1117-1123. DOI: 10.5768/JAO202243.0604010
    [3]PENG Huaxing, YAN Baojun, LIU Shulin, ZHANG Binting, WEI Wenlu. Graphical offline analysis software of electron multiplier pulse signals[J]. Journal of Applied Optics, 2022, 43(6): 1107-1116. DOI: 10.5768/JAO202243.0604009
    [4]CHEN Peng, YAN Xianze, HAN Yangyang, WU Chenyang, ZAN Hao. Nitrate nitrogen concentration detection method based on principal component analysis and BP neural network[J]. Journal of Applied Optics, 2020, 41(4): 761-768. DOI: 10.5768/JAO202041.0410002
    [5]ZHANG Wenying, ZHU Haoran. Error analysis and correction of circular grating angle measurement system[J]. Journal of Applied Optics, 2019, 40(3): 399-403. DOI: 10.5768/JAO201940.0301007
    [6]Xiao Shaorong, Zhou Weiwei. Analysis of Mie scattering spectrum based on guided filtering[J]. Journal of Applied Optics, 2017, 38(6): 923-930. DOI: 10.5768/JAO201738.0602004
    [7]Xu Dian, Lin Guanyu, Cao Diansheng, Xue Qingsheng. Accuracy analysis for wavelength scanning mechanism of double grating spectrometer[J]. Journal of Applied Optics, 2017, 38(1): 24-30. DOI: 10.5768/JAO201738.0101005
    [8]LI Yan, YANG Hong-ru, WANG Xue-wu, LI Xu-dong, WU Lei, YU Bing. Design of range-gated gain-control photomultiplier[J]. Journal of Applied Optics, 2009, 30(6): 1040-1044.
    [9]HUANG Ying, XIE Yan-hong, YI Xin-jian. Banknote recognition technology based on fluorescence spectrum analysis method[J]. Journal of Applied Optics, 2008, 29(4): 629-632.
    [10]XU Li-sheng, CHEN Wei, LI Jian-zhong, HU Fang-long. Application of photomultiplier tube in detection of cement grout density[J]. Journal of Applied Optics, 2007, 28(1): 102-104.

Catalog

    Article views (2931) PDF downloads (1270) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return