XU Ying-ying, CHEN Chi, WANG Jie, YIN Yu-zhe. Metrology device for photometric-colorimetric calibration of digital flat panel display[J]. Journal of Applied Optics, 2007, 28(2): 226-230.
Citation: XU Ying-ying, CHEN Chi, WANG Jie, YIN Yu-zhe. Metrology device for photometric-colorimetric calibration of digital flat panel display[J]. Journal of Applied Optics, 2007, 28(2): 226-230.

Metrology device for photometric-colorimetric calibration of digital flat panel display

More Information
  • Corresponding author:

    CHEN Chi

  • The measurement principle and standard set up for the photometric and colorimetric measurement of digital displays panel are presented. The display principles and characteristics of the major products such as CRT, LCD and PDP are introduced. The whole system was calibrated by standard lamp with the standard transferred from the national primary photometric and colorimetric standard. Incorporated with a new spectral detector and a data collection analysis software based on virtual interface technology, the system can measure the unit under test in real time. The uncertainty of the luminance and chromatic coordinates is better than 2% and 0.005 respectively. Major digital flat panel displays in the market are tested, and their parameters such as relative spectral response, luminance, luminance uniformity, contrast ratio, color gamut are calibrated. The test results and performance comparisons are given.
  • Related Articles

    [1]LI Heran, YUAN Qun, FAN Xiaoxin, ZHANG Jiale, MA Jianqiu, QIAO Wenyou, GAO Zhishan, GUO Zhenyan, LEI Lihua, FU Yunxia. Calibration method of topography error of white light interferometry on curved surface sample measurement[J]. Journal of Applied Optics, 2024, 45(2): 422-429. DOI: 10.5768/JAO202445.0203004
    [2]XING Lun, SANG Mei, SHI Zhenman, WANG Shuang, LIU Tiegen. White-light interference demodulation algorithm based on SVMD-HD denoising[J]. Journal of Applied Optics, 2023, 44(4): 816-825. DOI: 10.5768/JAO202344.0403002
    [3]ZHAI Zhongsheng, ZHANG Yi, FENG Wei, FENG Sheng, WANG Xuanze, XIONG Zhi. High sensitivity micro-displacement homodyne interferometry[J]. Journal of Applied Optics, 2022, 43(1): 74-80. DOI: 10.5768/JAO202243.0103001
    [4]KANG Jian, ZHANG Le, SHAN Yingshuang, CHEN Hao. Laser white light source of its optical system analysis[J]. Journal of Applied Optics, 2019, 40(5): 763-773. DOI: 10.5768/JAO201940.0501008
    [5]QIN Yi, GONG Qiong, LuXiao-dong, MA Mao-fen. Double image encryption system based on principles of interference[J]. Journal of Applied Optics, 2013, 34(2): 260-266.
    [6]SHEN Shao-meng, MA Jun, HE Xu. Alignment technology of portable Tyman-Green interferometer[J]. Journal of Applied Optics, 2011, 32(6): 1173-1179.
    [7]WEI Yong-qiang, ZOU Wen-dong, ZHAO Li-zhong, JI Hai-yan. Design of white-light interference micro/nano scanning system controlled by SPCE061A[J]. Journal of Applied Optics, 2009, 30(3): 391-396.
    [8]DU Shu-song, WANG Yong-mei, DU Guo-jun, WANG Ying-jian. Stray light analysis of Fabry-Perot interference imaging spectrometer[J]. Journal of Applied Optics, 2009, 30(2): 246-251.
    [9]FU Jian-wei, XIAO Li-zhi, YU Hui-jun. Reflection spectrum characteristics of FBG based on interference principle[J]. Journal of Applied Optics, 2008, 29(supp): 117-119.
    [10]WANG Zhong-lin, ZHENG Dan, SUN Dong-li. Measurement of optical sphere radius with white light interference[J]. Journal of Applied Optics, 2007, 28(6): 707-711.

Catalog

    Article views (2843) PDF downloads (791) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return