Zhou Dan, Xiang Yang, Gao Jian. Optical system design of autocollimation[J]. Journal of Applied Optics, 2014, 35(5): 794-798.
Citation: Zhou Dan, Xiang Yang, Gao Jian. Optical system design of autocollimation[J]. Journal of Applied Optics, 2014, 35(5): 794-798.

Optical system design of autocollimation

More Information
  • An novel high-precision intellectualized electronic digital display autocollimator for two-dimensional photometry was designed, which could be used to measure small angles.The wavelength of the system was 670 nm.The foldback system was adopted in order to reach 1 m focal length and reduce the volume of the system.The position sensitive detector (PSD) was used as the optical receiver so that the accuracy of the instrument was increased and could meet the requirements that the measurement range was 6 and the accuracy was 0.1. The optical path system of the autocollimator was designed and optimized by Zemax.The emergent rays were parallel and the rays received by the determinand were homogeneous as shown in footprint diagram.These results can meet the needs of practical manufacture well.
  • [1]Chen Ying,Zhang Xuedian,Lu Xinglian,et al. Current situation and development trend of auto-collimator[J]. OME Information,2011,28(1):6-9.
    陈颖,张学典,逯兴莲,等. 自准直仪的现状与发展趋势[J]. 光机电信息,2011,28(1):6-9.
    [2]Zhang Xinting. Research on high-precision and photoelectric auto-collimator[D]. Changchun:Changchun University of Science and Technology,2010:17-26.
    张欣婷. 高精度光电自准直仪研究[D]. 长春:长春理工大学,2010:1726.
    [3]Lu Jiugui,Gan Junhong,Ji Guoding. Research on high-precision and two-dimensional auto-collimator[J]. Metrology & Measurement Technology,2006,26(5):19-21.
    卢九贵,甘俊红,季国定. 高精度二维自准直仪的研制[J]. 计测技术,2006,26(5):19-21.
    [4]Yang Jingyue,Shao Yinmei,Zhang Rendai. The auto-collimator[M]. Beijing:China Machine Press,1982:3-5.
    杨靖岳,邵荫梅,张仁岱. 自准直仪[M].北京:机械工业出版社,1982:3-5.
    [5]Wang Wenming,Wang Anwei,Hu Chongan. Research and analysis on auto-collimation theory of military theodolite[J]. Journal of Applied Optics,1996,17(6):5-7.
    王文明,王安伟,胡崇安.军用经纬仪外自准直功能原理研究分析[J].应用光学,1996,17(6):5-7.
    [6]Bai Jianming. Research on measurement accuracy of wide field auto-collimation[D].Xi-an:Xidian University,2010:7-22.
    白建明. 大视场光电准直仪的准直测量精度研究[D]. 西安:西安电子科技大学,2010:7-22.
    [7]Wei Zhonghui. Design and research on electronic and photoelectric auto-collimator [J]. Optics and Precision Engineering,1996,4(3):116-120.
    魏仲慧. 数字光电自准直仪的研究与设计[J]. 光学精密工程,1996,4(3):116-120.
    [8]Huang Xiang,Wu Nianxiang. Research on angle measurement system based on PSD of photoelectric auto-collimator[J]. Manufacturing Automation,2011,33(6):39-41.
    黄祥,吴年祥. 基于PSD的光电自准直仪角度测量系统研究[J]. 制造业自动化,2011,33(6):39-41.
    [9]Ilev I K. Simple autocollimation laser refractometer with highly sensitive fiberoptic output[J]. Applied Optics,1995, 34 (10):1741-1743.
    [10]Zhu Fan, Tan Jiubin, Cui Jiwen. Beam splitting target reflector based compensation for angular drift of laser beam in laser autocollimation of measuring small angle deviations[J]. The Review of Scientific Instruments, 2013, 84 (6):124-131.
    [11]Chin Minghong,Su Derchin.Angle measurement using total-intemal-refleetion heterodyne interferometry[J]. Optical Engineering,1997,36(6):1750-1755.
  • Related Articles

    [1]WU Zhentao, ZHANG Rui, LI Wenyue, CHANG Yanxiang, WANG Yaqi, YANG Shuai, XUE Peng, WANG Zhibin. Rapid extraction algorithm of laser alarm spot center based on projection segmentation[J]. Journal of Applied Optics, 2024, 45(6): 1170-1178. DOI: 10.5768/JAO202445.0602001
    [2]LIU Zhesheng, ZHANG Dongdong, LI Hongyang, SONG Liwei, TIAN Ye. Optimization of linear laser beam pointing stability based on Gaussian process regression[J]. Journal of Applied Optics, 2023, 44(6): 1265-1272. DOI: 10.5768/JAO202344.0610014
    [3]YU Xiang, FU Rongguo, HUANG Mingzhu, GAO Jianpo, LYU Xing, MA Lingyun, ZHANG Huanan, YANG Qi. High precision center measurement of far-field laser based onimproved Zernike moments[J]. Journal of Applied Optics, 2023, 44(6): 1244-1249. DOI: 10.5768/JAO202344.0610011
    [4]YAO Linhai, LU Peiguo, YANG Yong'an, LONG Jingyu, YANG Xiulin, BU Yinghua. High precision measurement method of laser beam pointing stability[J]. Journal of Applied Optics, 2022, 43(2): 339-344. DOI: 10.5768/JAO202243.0207001
    [5]CHENG Xin, LING He, LI Shuo. Light bar center extraction algorithm for automotive weld sealant strips[J]. Journal of Applied Optics, 2019, 40(5): 823-828. DOI: 10.5768/JAO201940.0502006
    [6]Xiao Xingwei, Ma Guolu, Zeng Guoying. Centering method for non-diffracting spot images based on correlation-coefficient[J]. Journal of Applied Optics, 2018, 39(4): 500-504. DOI: 10.5768/JAO201839.0402003
    [7]hang Jing, Liu Ji, Liu Xiu, Zhang Bin, Li Shiwei. Spot location algorithm of weapon automata motion testing system[J]. Journal of Applied Optics, 2016, 37(3): 430-434. DOI: 10.5768/JAO201637.0303006
    [8]CUI Ju, WANG Hai-tao, CHEN Yong, WAN Min, ZHU Yong-kai, ZHAO Jian-ning. Distal location method of interlocking intramedullary nails based on gravity center of light spot[J]. Journal of Applied Optics, 2008, 29(6): 878-883.
    [9]TANG Shu-gang, DANG Li-ping, BAI Bo. Morphological filter algorithm to improve positioning accuracy of multi-laser convergent spot center[J]. Journal of Applied Optics, 2008, 29(5): 693-696.
    [10]LI You, ZHANG Heng, LEI Zhi-hui. Detection and tracking of light blobs based on center-surround mechanism of biological vision[J]. Journal of Applied Optics, 2008, 29(2): 283-288.

Catalog

    Article views (2297) PDF downloads (412) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return