LI You, ZHANG Heng, LEI Zhi-hui. Detection and tracking of light blobs based on center-surround mechanism of biological vision[J]. Journal of Applied Optics, 2008, 29(2): 283-288.
Citation: LI You, ZHANG Heng, LEI Zhi-hui. Detection and tracking of light blobs based on center-surround mechanism of biological vision[J]. Journal of Applied Optics, 2008, 29(2): 283-288.

Detection and tracking of light blobs based on center-surround mechanism of biological vision

More Information
  • Corresponding author:

    LI You

  • Based on the center-surround mechanism of biological vision, a method which uses an improved LoG (Laplacian of Gaussian) operator to detect light blobs is proposed. First of all, the imaging model of light blob targets was established. The properties of LoG operators and their response to image were analyzed and a normalized LoG operator was proposed. The normalized LoG operators can be used to detect light blobs according to theoretical deduction. Simulation and test show that the proposed operator is effective in detecting size-known and size-unknown blobs in an image. The proposed operator can also be used to track single target and rigid-body in image sequence if combined with Kalman filter or particle filter. This method is proven to be robust and effective.
  • Related Articles

    [1]YANG Xiaoyang, SHEN Manling, WANG Dahui, YANG Pengling, LI Xiangyang. Mid-infrared trap detector technology based on cryogenic integrating sphere[J]. Journal of Applied Optics, 2024, 45(4): 685-692. DOI: 10.5768/JAO202445.0401003
    [2]YE Wei, DU Pengfei, XIAO Sheng, LI Mengfei. Influence of InAlAs concentration on In0.83Al0.17As/In0.83Ga0.17As infrared detector characteristics[J]. Journal of Applied Optics, 2022, 43(2): 317-324. DOI: 10.5768/JAO202243.0204002
    [3]LI Yan, FAN Jihong, YU Bing, YUAN Lin'guang, SUN Yu'nan, QIN Yan, MA Li. Spectral responsivity measurement technology for UV detector based on cryogenic radiometer[J]. Journal of Applied Optics, 2022, 43(2): 311-316. DOI: 10.5768/JAO202243.0204001
    [4]Li Xue, Fang Bo, Deng Yuqiang, Li Jianmin, Qi Cenke, Cai Jinhui. High-precision responsivity calibration system for terahertz detector[J]. Journal of Applied Optics, 2018, 39(5): 691-696. DOI: 10.5768/JAO201839.0503003
    [5]JIAO Ming-yin. Optical design of searching system using 480×6 LWIR detector[J]. Journal of Applied Optics, 2012, 33(6): 1011-1013.
    [6]ZHANG Yang, ZHAG Ji-long, DU Xuan-yan. Weak signal detection circuit based on HgCdTe IR detector[J]. Journal of Applied Optics, 2011, 32(4): 779-783.
    [7]HUANG Chang-zhao, ZHANG Shu-qun, YAO Li-jun, DING Jia, HUANG Yong. ADesign of data acquisition system for near infrared detector[J]. Journal of Applied Optics, 2011, 32(1): 138-143.
    [8]TAO Kun-yu, LI Fu-wei, FU Sen, ZHOU Yan-ping. Error analysis and comparison of spectral responsivity calibration methods for HgCdTe-IRFPA imaging detector[J]. Journal of Applied Optics, 2007, 28(5): 587-592.
    [9]FAN Ji-hong, HOU Xi-qi, YANG Zhao-jin, YIN Tao, QIN Yan, LIU Jian-ping. Measurement technology for spectral responsivity of infrared detector[J]. Journal of Applied Optics, 2006, 27(5): 460-462.
    [10]FAN Ji-hong, YANG Zhao-jin, QIN Yan. Research of test technology for absolute spectral responsivity of HgCdTe detector[J]. Journal of Applied Optics, 2006, 27(supp): 79-82.

Catalog

    Article views (2854) PDF downloads (741) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return