ZHENG Ya-wei, QIANG Hua, GUO Yun-ping, GAO Jiao-bo, WANG Jun, LI Jun-na, GAO Ze-dong, WU Wen-li. Design and analysis of dual-channel infrared projection optical system[J]. Journal of Applied Optics, 2012, 33(2): 391-394.
Citation: ZHENG Ya-wei, QIANG Hua, GUO Yun-ping, GAO Jiao-bo, WANG Jun, LI Jun-na, GAO Ze-dong, WU Wen-li. Design and analysis of dual-channel infrared projection optical system[J]. Journal of Applied Optics, 2012, 33(2): 391-394.

Design and analysis of dual-channel infrared projection optical system

More Information
  • This paper analyzes ray paths of the dual-channel projection system and introduces the design of the projection collimator optics. The projection system consists of a target source generator and an inference source generator sharing the same optics. The optics uses a re-imaging configuration to meet the packaging requirement. The beam splitter is located between the last surface and the focal plane of the optics to combine the target source channel. By reducing the thickness of the beam splitter, the aberration of the optics in the inference source channel is reduced. The optics collimates the output from an infrared source in the 8 m~12 m waveband and enables an imaging system with 8.5 field of view to be tested. The effective focal length of the optics is 315.69 mm and the entrance pupil relief is 900 mm.The obtained performance shows the optics meet the requirements of the projection system.
  • [1]SAYLOR D A,BEASLEY D B .Current status of scene projection army aviation and missile command[J].SPIE, 2001, 4366:147-148.
    [2]王治乐,戴景民,杨迪.红外仿真变焦光学系统设计[J].应用光学,2008,29(6):936-937.
    WANG Zhi-le,DAI Jing-min ,YANG Di.Optical design of zoom lenses in IR HWIL simulation system[J]. Journal of Applied Optics, 2008,29(6): 936-937. (in Chinese with an English abstract)
    [3]ZHENG Ya-wei,GAO Jiao-bo,WANG Jun,et al.The optical system for dynamic scene simulation[J]. SPIE, 2005, 5638:338-339.
    [4]ZHENG Ya-wei,GAO Jiao-bo,WANG Jun,et al. Scene simulation optics in testing of dual-field angle infrared imager[J]. SPIE, 2007, 6834:68343X-1-68343X-2.
    [5]BEN-DAVID E, CABIB D .IR simulation of missile closing on a moving textured object with a textured background and EO countermeasure[J].SPIE, 1992, 1687:513-517.
    [6]潘洪涛,左保军.大入瞳距双通道红外投影系统设计[J].红外与激光工程,2009,38(3):506-507.
    PAN Hong-tao, ZUO Bao-jun. Dual-channel infrared projection system design with large entrance pupil distance [J].Infrared and Laser Engineering, 2009, 38(3):506-507. (in Chinese with an English abstract)
    [7]虞红.目标/星空背景光学特性仿真方法研究[J].红外与激光工程,2006,35 (4):470-471.
    YU Hong.Optical characteristis simulation approach of target/stars background [J].Infrared and Laser Engineering, 2006,35(3):470-471. (in Chinese with an English abstract)
    [8]丁旭明,熊望娥,於崇真,等. 红外耦合光学系统设计[J].应用光学,2006,27(5):400-410.
    DING Xu-ming,XIONG Wang-er ,YU Chong-zhen,et al .Optical design of coupling system [J]. Journal of Applied Optics, 2006,27(5): 400-410. (in Chinese with an English abstract)
    [9]WOLFE W L. Infrared design example[M].Washington :SPIE Press, 1999.
    [10]FISHCHER R E,TADIC-GALEB B . Optical system design[M].Washington:SPIE Press, 2000.
  • Related Articles

    [1]Xie Hongbo, Xu Mengmeng, Gong Yanxia, Fang Chunlun, Jiang Min, Meng Qingbin. Optical system design of widespectrum and ultra highspeed 8frame framing camera[J]. Journal of Applied Optics, 2016, 37(2): 172-176. DOI: 10.5768/JAO201637.0201004
    [2]ZHAI Wen-chao, XU Jun, DING Le, ZHENG Xiao-bing. Collimator design for novel spectral tunable calibration source system[J]. Journal of Applied Optics, 2013, 34(4): 570-574.
    [3]ZHAO Kun, CHE Chi-cheng. Wide spectral SWIR star sensor optical system[J]. Journal of Applied Optics, 2013, 34(1): 21-25.
    [4]ZHANG Xin-ting, LIU Ru-guang, AN Zhi-yong. Catadioptric photographic lens design for wide-bandhigh-resolution aerial camera[J]. Journal of Applied Optics, 2012, 33(6): 1035-1039.
    [5]CHEN Jiao, JIAO Ming-yin, CHANG Wei-jun, KANG Wen-li, HU Bo, ZHANG Feng-juan, CUI Hai-yun. Optical design of apochromatic microscope objective for near ultraviolet-visible wide spectrum[J]. Journal of Applied Optics, 2011, 32(6): 1098-1102.
    [6]CHEN Jiao, JIAO Ming-yin, CHANG Wei-jun, KANG Wen-li. Optical design of microscopic imaging system for ultraviolet-visiblewide spectrum[J]. Journal of Applied Optics, 2011, 32(2): 195-199.
    [7]WANG Mei-qin, WANG Zhong-hou, BAI Jia-guang. Removing secondary spectrum in wide spectrum optical system[J]. Journal of Applied Optics, 2010, 31(3): 360-364.
    [8]GUO Cheng, WANG Gao-ming, ZHANG Liang-liang, YANG Zhi-wen. Design of wide spectrum low-light-level collimating lens[J]. Journal of Applied Optics, 2009, 30(2): 199-201.
    [9]HAN Ming, LIN Xiao-chun, AN Yu-ying. Design of complex testing system for flame spectrum and image[J]. Journal of Applied Optics, 2007, 28(3): 341-344.
    [10]HONG Wen-xue, CAI Jian-hong, JING Jun. A Research on Heat Radiation Spectrum Characteristics of Moxibustion Therapy[J]. Journal of Applied Optics, 2004, 25(4): 1-3.

Catalog

    Article views (3451) PDF downloads (704) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return