FAN Ji-hong, HOU Xi-qi, YUAN Liang, YANG Bin, QIN Yan, SONG Jin-hong. High reflectance and high transmittance measurement for optical elements[J]. Journal of Applied Optics, 2011, 32(6): 1184-1188.
Citation: FAN Ji-hong, HOU Xi-qi, YUAN Liang, YANG Bin, QIN Yan, SONG Jin-hong. High reflectance and high transmittance measurement for optical elements[J]. Journal of Applied Optics, 2011, 32(6): 1184-1188.

High reflectance and high transmittance measurement for optical elements

  • In order to measure high reflectance and high transmittance of optic components and coat films, a precise measurement facility was set up which was based on single reflection measurement using laser power-stabilized technique, double optical path measurement technique and precise detection technique. High reflectance and high transmittance were measured at 632.8 nm and 1 064 nm wavelengths on the facility. Experiment result and uncertainty analysis showed that the measurement uncertainty of high reflectance and high transmittance was less than 0.008% at 632.8 nm and was less than 0.015% at 1 064 nm.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return