TAN Yi, HUANG Xin-min, REN Ya-jie. Influence of transducer bandwidth on photo-acoustic imaging resolution[J]. Journal of Applied Optics, 2011, 32(5): 831-834.
Citation: TAN Yi, HUANG Xin-min, REN Ya-jie. Influence of transducer bandwidth on photo-acoustic imaging resolution[J]. Journal of Applied Optics, 2011, 32(5): 831-834.

Influence of transducer bandwidth on photo-acoustic imaging resolution

More Information
  • In order to research the influence of different bandwidths of transducer on photo-acoustic imaging resolution, finite element simulation experiments were carried out. An empirical formula was obtained between transducer bandwidth and photo-acoustic imaging resolution. Experimental results showed that the reconstructed image resolution of absorbers was unchanged in the order of millimeters when the cut-off frequency of transducer was greater than 2 MHz; however, it was contrary for the frequency less than 2 MHz. The results are helpful for the choice of transducer and the evaluation of image reconstruction.
  • [1]谭毅. 基于滤波反投影的光声图像重建 [J]. 应用光学, 2011, 32(3):468-471.

    TAN Yi. Photoacoustic imaging based on filtered back projection [J]. Journal of Applied Optics, 2011,32(3):468-471. ( in Chinese with an English abstract)

    [2]谭毅, 何军锋, 曹吉利,等. 生物组织高对比度的快速光声层析成像[J]. 激光技术, 2008,32(5):551-553.

    TAN Yi, He Jun-feng, Cao Ji-li, et al. High-contrast and fast photoacoustic image of tissue [J]. Laser Technology, 2008, 32(5):551-553. ( in Chinese with an English abstract)

    [3]LAUFER J, ZHANG E, RAIVICH G, et al. Three-dimensional noninvasive imaging of the vasculature in the mouse brain using a high resolution photoacoustic scanner [J].Applied Optics, 2009, 48(10): 299-306.

    [4]卢涛, 毛慧勇, 臧海河. 活体白鼠脑血管时域光声成像的实验研究[J].医疗卫生装备, 2009,30(12):18-20.

    LU Tao,MAO Hui-yong, ZANG Hai-he. Time-domain photoacoustic tomography of mouse brain vessel in vivo [J]. Chinese Medical Equipment Journal, 2009, 30(12):18-20. ( in Chinese with an English abstract)

    [5]YANG X M, MAURUDIS A, GAMELIN J, et al. Photoacoustic tomography of small animal brain with a curved array transducer [J]. Journal of Biomedical Optics, 2009, 14(5):0540071 -0540075.

    [6]YANG Si-Hua, YIN Guang-Zhi, XING Da. Pharmacokinetic monitoring of indocyanine green for tumor detection using photoacoustic imaging [J]. Chin. Phys. Lett., 2010, 27(9):0943021-0943024.

    [7]Li M L, OH J T, XIE X Y, et al. Simultaneous molecular and hypoxia imaging of brain tumors in vivo using spectroscopic photoacoustic tomography [J].  IEEE, 2008, 96(3):481-489.

    [8]胡军,邢达,杨迪武,等. 光声层析成像技术在骨坏死早期诊断中的应用[J]. 生物化学与生物物理进展, 2008,35(11):1326-1331.

    HU Jun, XING Da, YANG Di-wu, et al. The Application of Photoacoustic Image in the Diagnosis of Early Stage Osteonecrosis [J]. Progress in Biochemistry and Biophysics, 2008, 35(11):1326-1331. ( in Chinese with an English abstract)

    [9]徐晓辉, 李晖. 基于长焦区聚焦换能器的扫描光声乳腺成像技术[J]. 物理学报, 2008,57(7):4623-4626.

    XU Xiao-hui, LI Hui. Scanning Photoacoustic Mammography with a focused transducer featuring extended focal zone [J]. Acta Physica Sinica, 2008, 57(7):4623-4626. ( in Chinese with an English abstract)

    [10]WEI Y D, TANG Z L, ZHANG H C et al. Photoacoustic tomography imaging using a 4f acoustic lens and peak-hold technology [J]. Optics Express, 2008, 16(8): 5314-5319.

    [11]YANG D W, XING D, TAN Y et al. Integrative prototype B-scan photoacoustic tomography system based on a novel hybridized scanning head [J]. Applied Physics Letter, 2006, 88(17):174101-174103.

    [12]MA S B, YANG S H and XING D. Photoacoustic imaging velocimetry for flow-field measurement [J]. Optics Express, 2010, 18(10): 9991-10000.

    [13]卢涛, 李秀娟, 毛慧勇, 等. 基于维纳滤波反卷积的光声成像[J].光学学报, 2009,29(7):1854-1857.

    LU Tao, LI Xiu-juan, MAO Hui-yong et al. Photoacoustic tomography with wiener filter deconvolution algorithm [J]. Acta Optica Sinica, 2009,29(7):1854-1857. ( in Chinese with an English abstract)

    [14]TAO C, LIU X J. Reconstruction of high quality photoacoustic tomography with a limited-view scanning [J]. Optics Express, 2010, 18(3): 2760-2766.

    [15]XU M H, WANG L V. Time-domain reconstruction for thermoacoustic tomography in a spherical geometry [J].  IEEE Trans. Med. Imaging, 2002, 21(7):814-822.

    [16]吴丹, 陶超, 刘晓峻. 有限方位扫描的光声断层成像分辨率研究[J]. 物理学报, 2010,59(8):5846-5851.

    WU Dan, TAO Chao, LIU Xiao-Jun. Study of the resolution of limited-view photoacoustic tomography [J]. Acta Physica Sinica, 2010,59(8):5846-5851. ( in Chinese with an English abstract)

    [17]谭毅, 邢达, 王毅, 等. 超声换能器带宽对光声成像的影响[J]. 光学学报, 2005,25(1):40-44.

    TAN Yi, XING Da, WANG Yi, et al. Influence of bandwidth of ultrasonic transducer on photoacoustic imaging [J]. Acta Optica Sinica, 2005,25(1):40-44. ( in Chinese with an English abstract)

    [18]KU G, WANG X D, STOICA G, et al. Multiple-bandwidth photoacoustic tomography [J].  Physics in Medicine and Biology, 2004, 49(7):1329-1338.
  • Related Articles

    [1]WANG Xiaoxiao, ZENG Xingchang, WANG Zhijie, LI Yongfeng, HUANG Yi, ZHU Shengwei. Precision assembly and testing for imaging detector in photoelectric imaging system[J]. Journal of Applied Optics, 2025, 46(1): 163-169. DOI: 10.5768/JAO202546.0105001
    [2]LI Zhipeng, ZHAO Changming, ZHANG Haiyang, ZHANG Zilong, WU Xuan. Application of multi-scale fusion super-resolution algorithm in UAV detection[J]. Journal of Applied Optics, 2021, 42(3): 462-473. DOI: 10.5768/JAO202142.0302003
    [3]CHEN Yufang, WU Zhencong, WANG Min. Design and application of optical system for high-resolution micro space-borne camera[J]. Journal of Applied Optics, 2020, 41(2): 235-241. DOI: 10.5768/JAO202041.0201001
    [4]Liu Shulin, Yang Luping, Dong Yuhui, Huang Mingju, Su Detan, Yan Baojun, Wen Kaile, Qi Huirong, Yang Yuzhen, Yu Yang. High-resolution X-ray CCD camera based on the first generation image intensifier[J]. Journal of Applied Optics, 2017, 38(5): 810-814. DOI: 10.5768/JAO201738.0505001
    [5]LI Wei. High-resolution X-ray digital radiography of electronic industry[J]. Journal of Applied Optics, 2012, 33(4): 654-659.
    [6]SHI Ji-fang, SUN Yu-nan, XIE Qi, LI Hong-guang, WU Li-peng, HAN Zhan-suo, WANG Sheng-yun, YANG Bing. Resolution measurement of third generation LLL image intensifier[J]. Journal of Applied Optics, 2012, 33(1): 144-147.
    [7]LIU Jia, HE Feng-tao. High-resolution 405 nm laser microscopic imaging[J]. Journal of Applied Optics, 2011, 32(4): 806-809.
    [8]HAN Jun, XUE Xiao-le, WANG Xing. ASuper-resolution imaging technology for optical imaging system[J]. Journal of Applied Optics, 2011, 32(1): 54-58.
    [9]CHENG Yao-jin, SHI Feng, GUO Hui, ZHU Yu-feng, Yuan Xiao-man. Effect of MCP parameters on resolution of image intensifier[J]. Journal of Applied Optics, 2010, 31(2): 292-296.
    [10]ZHANG Dong-ling, HE Feng-tao, FENG Xiao-qiang, HOU Xun. Highresolution Optical MicroSurvey System with Blue Illuminating Source[J]. Journal of Applied Optics, 2005, 26(3): 57-59.

Catalog

    Article views (3718) PDF downloads (631) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return