CHENG Yao-jin, SHI Feng, GUO Hui, ZHU Yu-feng, Yuan Xiao-man. Effect of MCP parameters on resolution of image intensifier[J]. Journal of Applied Optics, 2010, 31(2): 292-296.
Citation: CHENG Yao-jin, SHI Feng, GUO Hui, ZHU Yu-feng, Yuan Xiao-man. Effect of MCP parameters on resolution of image intensifier[J]. Journal of Applied Optics, 2010, 31(2): 292-296.

Effect of MCP parameters on resolution of image intensifier

More Information
  • The performance of microchannel plate (MCP) is very important for the resolution of image intensifier. In order to analyze the impact of MCP parameters on the resolution of image intensifier, the transverse scattering of electrons from the output surface of MCP and the elastic scattering of electrons from the non-open surface of MCP were investigated by using electron scattering theory. The results show that the resolution of image intensifier can be improved by reducing channel distance, using multilayer electrodes, increasing the depth of output electrode and increasing open area ratio.
  • [1]周立伟,刘玉岩.目标探测与识别[M].北京:北京理工大学出版社,2002.
    ZHOU Li-wei, LIU Yu-yan. Target recognition and detection[M].Beijing: Beijing Institute of Technology Press, 2002.(in Chinese)
    [2]程耀进,向世明,师宏立.三代微光像增强器分辨力计算理论模型[J].应用光学,2007,28(5):578-581.
    CHENG Yao-jin, XIANG Shi-ming, SHI Hong-li. Theoretical model for resolution calculation of third generation image intensifiers[J].Journal of Applied Optics,2007,28(5): 578-581.(in Chinese with an English abstract)
    [3]向世明.双近贴聚焦微光像增强器分辨力理论极限问题研究[J].应用光学,2008,29(3):351-353.
    XIANG Shi-ming. Theoretical resolution limit of double-proximity focusing image intensifiers[J].Journal of Applied Optics,2008,29(3):351-353.(in Chinese with an English abstract)
    [4]潘京生.微通道板及其主要特征性能[J].应用光学,2005,25(5):25-29.
    PAN Jin-sheng. Microchannel plates and its main characteristics[J].Journal of Applied Optics,2005,25(5):25-29.(in Chinese with an English abstract)
    [5]ESTRERA J P,SALDANA M R.Gated power su-pply technologies for advanced image intensifiers[J].SPIE,2003,4796:60-70.
    [6]JACKSEN N F.Bonding method for microchannel plates[P].US,7021522[P].2006-04-04.
    [7]ROSINE S D,DEVOE N C.Microchannel plate having microchannels with deep funneled and/or step funneled openings and method of manufacturing same[P]. US,6876802[P].2005-04-05.
    [8]SIEGMUND O HW, TREMSIN A S, VALLERGA J V.Advanced MCP sensors for UV/visible astronomy and biology[J].Nuclear Instruments and Methods in Physics Research A, 2003,510:185-189.

Catalog

    Article views (3064) PDF downloads (1066) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return