Double-channel digital IR radiometer

More Information
  • The double-channel digital IR radiometer was developed for eliminating the disadvantages of the IR radiance testing system being used in testing some military infrared products. The double channels simultaneously test the IR radiance and connect the data when the ignition test of an IR radiation product is carried out. Six contrast experiments between the double-channel digital IR radiometer and IR radiance testing system were performed at 25℃ and -15℃. The result indicates that the error of the two systems are all less than 5%, and the difference of the two channels of the double-channel digital IR radiometer is also less than 5%. But 1905A testing system missed out twice and the radiator did not omit anything. The principle, design of key components, calibration and application are discussed in this paper.
  • [1]A.R.杰哈.红外应用技术[M]. 张孝霖,陈世达,舒郁文,等译.北京:化学工业出版社,2004.
    A.R.Jieha.IR application technology[M]. Translated by ZHANG Xiao-shen,CHEN Shi-da,SHU Yu-wen,et al.Beijing:Chemical Industry Press,2004.(in Chinese)
    [2]陈永甫.红外辐射器件与典型应用[M].北京:电子工业出版社,2004.
    CHEN Yong-pu.IR radiation device and typical application[M].Beijing:Publishing House of Electronics Industry,2004.(in Chinese)
    [3]王汝琳,王咏涛.红外检测技术[M].北京:化学工业出版社,2006.
    WANG Ru-lin,WANG Yong-tao.IR detection technology[M].Beijing: Chemical Industry Press,2006.(in Chinese)
  • Related Articles

    [1]ZHANG Youjun, ZHANG Chijian, XIE Wanyi, LIU Yong, XIA Yingwei, WANG Yiren. Calibration of external parameters of binocular cloud height system based on odometer method[J]. Journal of Applied Optics, 2021, 42(3): 522-526. DOI: 10.5768/JAO202142.0303005
    [2]ZHAO Tingting, BAI Fuzhong, XU Yongxiang, GAO Xiaojuan. Simple correction method for projection fringe period based on parameter calibration[J]. Journal of Applied Optics, 2021, 42(1): 119-124. DOI: 10.5768/JAO202142.0103004
    [3]CUI Enkun, TENG Yanqing, LIU Jiawei. Calibration error compensation technique of stereoscopic vision measurement system[J]. Journal of Applied Optics, 2020, 41(6): 1174-1180. DOI: 10.5768/JAO202041.0601006
    [4]ZHANG Yunxiang, LI Xin, LI Chen, ZHENG Xiaobing. Design and performance test of self-calibration multichannel infrared radiometer[J]. Journal of Applied Optics, 2020, 41(4): 743-753. DOI: 10.5768/JAO202041.0406004
    [5]Xiong Xin, Sun Dong-mei, Fan Wen, Xu Hai-peng. Calibration technique of binocular vision measurementsystem using light pen[J]. Journal of Applied Optics, 2015, 36(5): 784-790. DOI: 10.5768/JAO201536.0503004
    [6]ZHANG Lei, WANG An-guo, LI Hui, SHI Yi, ming. Accurate calibration method for optical system based on zenith observation[J]. Journal of Applied Optics, 2012, 33(5): 855-861.
    [7]HUANG Li-na, YU Zhong-qiu. Parameters calibration algorithm in electronic whiteboard system[J]. Journal of Applied Optics, 2012, 33(2): 271-277.
    [8]CHANG Fang-Fei, ZHANG Zhi-Min. Error analysis of common iterative reconstruction algorithmsin optical chromatographic technique[J]. Journal of Applied Optics, 2009, 30(4): 616-621.
    [9]YU Fen-qi, LEI Jin-li. Simulation realization of nonlinear camera calibration[J]. Journal of Applied Optics, 2008, 29(supp): 124-126.
    [10]TAO Kun-yu, LI Fu-wei, FU Sen, ZHOU Yan-ping. Error analysis and comparison of spectral responsivity calibration methods for HgCdTe-IRFPA imaging detector[J]. Journal of Applied Optics, 2007, 28(5): 587-592.

Catalog

    Article views (4020) PDF downloads (880) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return