LIU Shu-lin, DONG Yu-hui, SUN Jian-ning, DENG Guang-xu. Relation between signal-to-noise ratio of LLL image intensifier and voltage of MCP[J]. Journal of Applied Optics, 2009, 30(4): 650-653.
Citation: LIU Shu-lin, DONG Yu-hui, SUN Jian-ning, DENG Guang-xu. Relation between signal-to-noise ratio of LLL image intensifier and voltage of MCP[J]. Journal of Applied Optics, 2009, 30(4): 650-653.

Relation between signal-to-noise ratio of LLL image intensifier and voltage of MCP

  • In order to reveal the influence of the voltage variation of microchannel plate on the signal-to-noise ratio of LLL image intensifier and optimize the performance of the image intensifier, the curves that the signal-to-noise ratio of super Gen II and Gen III image intensifiers variates with the voltage of a microchannel plate were obtained by the aid of a signal-to-noise ratio tester. As for the super Gen II image intensifier, when the microchannel plates voltage is in the range of 600~800V, the signal-to-noise ratio is monotonically increased to 25.9, when it is in the range of 800~900V, the ratio is 25 or so and has downtrend, and when 900~1000V, the ratio is rapidly decreased to 21.8. As for the Gen III image intensifier, when the microchannel plates voltage is in the range of 800~1000V, the signal-to-noise ratio is monotonically increased to 27.87, and when the voltage is in 1000~11800V, the ratio fluctuates from 26.61 to 28.66.In combination with the theoretical analysis of microchannel plates noise factor, a method to reduce the noise factor of microchannel plates and improve the signal-to-noise ratio of LLL image intensifiers is proposed.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return