LI Gao-ping, YU Shuai, YANG Hong-ru, YANG Bin, WANG Lei. Study on effect of heat loss on energy measurement result of CW high energy laser[J]. Journal of Applied Optics, 2006, 27(supp): 37-40.
Citation: LI Gao-ping, YU Shuai, YANG Hong-ru, YANG Bin, WANG Lei. Study on effect of heat loss on energy measurement result of CW high energy laser[J]. Journal of Applied Optics, 2006, 27(supp): 37-40.

Study on effect of heat loss on energy measurement result of CW high energy laser

More Information
  • Corresponding author:

    LI Gao-ping

  • Received Date: July 09, 2006
  • Revised Date: July 29, 2006
  • The energy measurement result of CW highenergy laser, acquired by the calorimetric method and traditional data processing method, is influenced greatly by the heat loss as the laser pulse duration can be up to 30s. The effect of heat loss (including heat radiation, thermal conduction and heat transfer) on energy measurement result of CW high energy laser is studied in this paper. An experiment setup and the mathematical model of timetemperature relation were built up,and the correctness of the mathematical model were verified by experiments. The temperature rising curve of the taper energy absorbing cavity according to the relative expression with a corresponding data processing model has been gained. Based on the mathematical model, the measurement result is fitted with the least square method and the fitted curve tallies with the practical curve quite well. The measurement result was corrected by the data processing model. The energy measurement result shows that the measurement uncertainty is within 1%.
  • Related Articles

    [1]CAI Ying. Design of wide-band and high-precision laser energy meter[J]. Journal of Applied Optics, 2022, 43(3): 488-495. DOI: 10.5768/JAO202243.0303004
    [2]QIN Yan, HAN Zhansuo, LIN Lihong, WANG Jiangang, LI Jie, WANG Bing, YANG Hongru. Study on calibration system and method of femtojoule laser energy meter[J]. Journal of Applied Optics, 2020, 41(4): 711-716. DOI: 10.5768/JAO202041.0407004
    [3]LI Gao-ping, YANG Hong-ru, YANG Bin, YUE Wen-long, YIN Wan-hong, YU Dong-yu, XIE Yi. High-accuracy optical calibration technology for absolute-absorbing laser energy meter[J]. Journal of Applied Optics, 2014, 35(3): 438-440.
    [4]YANG Ye-ping, HOU Min, LI Gao-ping, YANG Bin, YU Shuai. Pyroelectric laser energy meter used in non-regular ambient environment[J]. Journal of Applied Optics, 2012, 33(4): 752-755.
    [5]YU Shuai, LI Gao-ping, SANG Peng, WU Yao. Bulk absorption laser calorimeter operating in non-standard environment[J]. Journal of Applied Optics, 2009, 30(4): 646-649.
    [6]WU Yao, LI Gao-ping, YU Shuai, WU Lei. Measurement method of thermal loss coefficient of calorimetric laser energy meter[J]. Journal of Applied Optics, 2008, 29(3): 398-402.
    [7]YU Shuai, LI Gao-ping, YANG Zhao-jin, WU Yao, SANG Peng, GUO Yu. Energy loss compensation of bulk absorption laser energy meter[J]. Journal of Applied Optics, 2007, 28(5): 659-662.
    [8]YANG Ye-ping, LI Gao-ping, YANG Bin, WANG Lei. Application of in situ laser energy metrology[J]. Journal of Applied Optics, 2007, 28(4): 508-512.
    [9]SHI Ji-fang, SONG Yi-bing, JI Xiao. Evaluation of uncertainty measurement for laser energy meter[J]. Journal of Applied Optics, 2006, 27(supp): 47-50.
    [10]WANG Lei, YANG Zhao-jin, Li Gao-ping, LIANG Yan-xi. Research on Temperature Characteristics of Absolute Calorimetric Energy Meter for HighEnergy Laser[J]. Journal of Applied Optics, 2005, 26(5): 29-032.

Catalog

    Article views (2761) PDF downloads (827) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return