Research on measurement of spectral radiance luminance base on hightemperature blackbody
-
-
Abstract
A method to measure the spectral radiance luminance is introduced. The spectral radiance luminance at the exit of a largediameter hightemperature blackbody was reconstructed with the method based on a hightemperature blackbody. At the same time, the acquired magnitude of the spectral radiance luminance for the standard lamp is transferred by the aid of the relative method. It is found that the acquired magnitude has lower measurement uncertainty. The measurement results are presented in this paper. BB3200K hightemperature blackbody and its measurement system are briefly introduced. The higher stability and satisfactory measuring result were obtained with the system into which an optical feedback system and an accurate temperaturemeasurement system were incorporated.
-
-