LI Chen, LIAO Jin-kun, JIANG Ya-dong, LI Wei, LU Rong-guo, HAN Li-kun, GAO Yu. Taylor series expansion method for TM mode of polymer waveguide M-Z modulator[J]. Journal of Applied Optics, 2008, 29(2): 313-316.
Citation: LI Chen, LIAO Jin-kun, JIANG Ya-dong, LI Wei, LU Rong-guo, HAN Li-kun, GAO Yu. Taylor series expansion method for TM mode of polymer waveguide M-Z modulator[J]. Journal of Applied Optics, 2008, 29(2): 313-316.

Taylor series expansion method for TM mode of polymer waveguide M-Z modulator

More Information
  • Corresponding author:

    LI Chen

  • Mach-Zehnder waveguide is an important part in integrated optics. The transverse distribution of refractive index of polymeric ridge waveguide was calculated with the effective index method (EIM) and 3-D propagation was converted into 2-D propagation according to the structural characteristics of the polymeric ridge waveguide. Based on paraaxial scalar equation, using CrankNicholson scheme, the basic calculation scheme of Taylor series expansion method was obtained and optimized. By simulating the TM mode of a real Mach-Zehnder waveguide, the influence of various parameters on the loss was analyzed. The results show that this method is accurate, stable and easy to program.
  • Related Articles

    [1]ZHANG Youjun, ZHANG Chijian, XIE Wanyi, LIU Yong, XIA Yingwei, WANG Yiren. Calibration of external parameters of binocular cloud height system based on odometer method[J]. Journal of Applied Optics, 2021, 42(3): 522-526. DOI: 10.5768/JAO202142.0303005
    [2]ZHAO Tingting, BAI Fuzhong, XU Yongxiang, GAO Xiaojuan. Simple correction method for projection fringe period based on parameter calibration[J]. Journal of Applied Optics, 2021, 42(1): 119-124. DOI: 10.5768/JAO202142.0103004
    [3]CUI Enkun, TENG Yanqing, LIU Jiawei. Calibration error compensation technique of stereoscopic vision measurement system[J]. Journal of Applied Optics, 2020, 41(6): 1174-1180. DOI: 10.5768/JAO202041.0601006
    [4]ZHANG Yunxiang, LI Xin, LI Chen, ZHENG Xiaobing. Design and performance test of self-calibration multichannel infrared radiometer[J]. Journal of Applied Optics, 2020, 41(4): 743-753. DOI: 10.5768/JAO202041.0406004
    [5]Xiong Xin, Sun Dong-mei, Fan Wen, Xu Hai-peng. Calibration technique of binocular vision measurementsystem using light pen[J]. Journal of Applied Optics, 2015, 36(5): 784-790. DOI: 10.5768/JAO201536.0503004
    [6]ZHANG Lei, WANG An-guo, LI Hui, SHI Yi, ming. Accurate calibration method for optical system based on zenith observation[J]. Journal of Applied Optics, 2012, 33(5): 855-861.
    [7]HUANG Li-na, YU Zhong-qiu. Parameters calibration algorithm in electronic whiteboard system[J]. Journal of Applied Optics, 2012, 33(2): 271-277.
    [8]CHANG Fang-Fei, ZHANG Zhi-Min. Error analysis of common iterative reconstruction algorithmsin optical chromatographic technique[J]. Journal of Applied Optics, 2009, 30(4): 616-621.
    [9]YU Fen-qi, LEI Jin-li. Simulation realization of nonlinear camera calibration[J]. Journal of Applied Optics, 2008, 29(supp): 124-126.
    [10]TAO Kun-yu, LI Fu-wei, FU Sen, ZHOU Yan-ping. Error analysis and comparison of spectral responsivity calibration methods for HgCdTe-IRFPA imaging detector[J]. Journal of Applied Optics, 2007, 28(5): 587-592.

Catalog

    Article views (3909) PDF downloads (987) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return