TAN Bi-tao, ZHANG Xin, JING Chun-yuan, YIN Shao-hui. Optical transfer function under normative optical fractional Fourier transform[J]. Journal of Applied Optics, 2008, 29(2): 211-215.
Citation: TAN Bi-tao, ZHANG Xin, JING Chun-yuan, YIN Shao-hui. Optical transfer function under normative optical fractional Fourier transform[J]. Journal of Applied Optics, 2008, 29(2): 211-215.

Optical transfer function under normative optical fractional Fourier transform

More Information
  • Corresponding author:

    TAN Bi-tao

  • Received Date: April 08, 2007
  • Revised Date: May 10, 2007
  • Based on the normative fractional Fourier transform and the concept of the optical transfer function, using the linear system theory, the mathematic expressions of fractional transfer function in Fresnel diffraction system and Fraunhofer diffraction system are given respectively. It is proved that the fractional Fourier transform has the cascade feature, and the optical transfer function is the special case of fractional transfer function. The result can be used to support the application of fractional Fourier transform in information processing and image quality assessment.
  • Related Articles

    [1]Li Xiao-ming, Shen Xue-ju, Li Gang, Liu Xun. Misalignment of KTP crystal in frequency-doubled laser[J]. Journal of Applied Optics, 2015, 36(3): 463-468. DOI: 10.5768/JAO201536.0305004
    [2]MAO Xin, SHEN Zhao-guo, FU Jie, TANG Gang-feng, YANG Yi, CHENG Jian-xin. LD side-pumped Nd∶GdVO4 532 nm green laser[J]. Journal of Applied Optics, 2013, 34(1): 152-155.
    [3]MENG Dong-dong, TANG Gang-feng, SHEN Zhao-guo, MAO Xin, YANG Yi. 2.12 μm laser pumped by Zig-Zag slab[J]. Journal of Applied Optics, 2012, 33(5): 991-995.
    [4]REN Cheng, ZHANG Shu-lian. Abnormal intensity noises of LD-pumped microchip Nd∶YAG laser[J]. Journal of Applied Optics, 2012, 33(3): 609-613.
    [5]PAN Jiang-ni, REN Zhao-yu, GUO Teng, WANG Si-yuan, BAI Jin-tao. High efficiency LD side-pumped green laser[J]. Journal of Applied Optics, 2012, 33(2): 411-414.
    [6]LI Gang, NING Zi-li, YANG Ai-fen, HAN Yao-feng. Eye-safe repetition laser based on optical parametric oscillator[J]. Journal of Applied Optics, 2011, 32(3): 579-581.
    [7]ZHANG Qiang, WANG Yue-feng, ZHU Xiao-peng, HOU Jun-yan, WEI Ming. Stability of LD dual-end pumped U-folded resonator Nd∶YVO4 laser[J]. Journal of Applied Optics, 2010, 31(6): 1027-1031.
    [8]ZHANG Hao-lei, CHEN Xiu-yan, LI Xiu, CHEN Hao-wei, REN Zhao-yu, BAI Jin-tao. Internally frequency-doubled hectowatt-level Nd∶YAG/KTP green laser side-pumped by LD[J]. Journal of Applied Optics, 2009, 30(5): 874-878.
    [9]WANG Juan-juan, WANG Jia-xian. LD-pumped Nd∶YVO4/KTP frequency-doubled red laser with folded resonator[J]. Journal of Applied Optics, 2008, 29(1): 67-71.
    [10]XU Hai-ping, XU Hai-yan, ZHANG Peng, REN Zhao-yu, BAI Jin-tao. LD side-pumped Nd∶YAG/S-KTP intracavity frequency doubled high power CW red laser at 660nm[J]. Journal of Applied Optics, 2007, 28(3): 332-335.

Catalog

    Article views (3240) PDF downloads (1001) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return