  • The expression between reflex light-tube installation error and emergent beam axis, as well as the calculation formula of the luminous energy loss was derived based on theoretical analysis for the light transmission characteristic of the reflex light-tube in the azimuth pointing system of missiles. The selection principle of the reflex light-tube structure version was summarized. The theoretical foundation for the reflex light-tube applied in the azimuth pointing systems of missiles is provided.
  • Related Articles

    [1]ZHU Guangyi, JIN Shangzhong, WU Lei, XUE Yuanyuan, MO Yunlong, YOU Yue, ZHANG Yunlong, YU Bing, YANG Hongru, DONG Zaitian, LU Fei. Peak power measurement device of terawatt femtosecond pulsed laser and measurement uncertainty analysis[J]. Journal of Applied Optics, 2024, 45(2): 398-404. DOI: 10.5768/JAO202445.0203001
    [2]Xiao Shaorong, Huang Biao, Huang Xing, Zhou Weiwei. Effect of bandpass filter on uncertainty of visibility measurement[J]. Journal of Applied Optics, 2016, 37(5): 712-718. DOI: 10.5768/JAO201637.0503001
    [3]Li Zhi-feng, Zhao Deng-feng, Ma Guo-lu, Zeng Guo-ying, Lu Zhan. Bending and torsion measuring system of rotary parts and it’s uncertainty analysis[J]. Journal of Applied Optics, 2015, 36(5): 778-783. DOI: 10.5768/JAO201536.0503003
    [4]WANG Xu, WANG Zhong-yu, ZHAO Wei-qian, QIU Li-rong. Uncertainty evaluation in laser differential confocal radius-of-curvature measurement[J]. Journal of Applied Optics, 2014, 35(1): 155-158.
    [5]FU Jie, SHEN Zhao-guo, CHENG Jian-xin, TANG Gang-feng, MAO Xin, YANG Yi. Intra-cavity frequency--doubled Nd∶YVO4/LBO red laser with high repetition rate[J]. Journal of Applied Optics, 2013, 34(5): 874-877.
    [6]FU Jie, SHEN Zhao-guo, TANG Gang-feng, MAO Xin, CHENG Jian-xin, YANG Yi. High repetition rate PPLT eye-safe laser with 1.06 μm pumping[J]. Journal of Applied Optics, 2013, 34(1): 156-160.
    [7]LIU Hao, MA Ping. Uncertainty analysis of laser calorimetry[J]. Journal of Applied Optics, 2011, 32(5): 942-948.
    [8]CHEN Jie-chun, ZHAO Li-ping, GUO ming. Uncertainty evaluation of corner detection[J]. Journal of Applied Optics, 2011, 32(3): 477-481.
    [9]WANG Hong-hong, CHEN Fang-bin, JIANG Tao, LI Guang-liang. Adaptive SMC for nonlinear optoelectronic servo ystem with uncertainty[J]. Journal of Applied Optics, 2009, 30(2): 242-245.
    [10]SHI Ji-fang, SONG Yi-bing, JI Xiao. Evaluation of uncertainty measurement for laser energy meter[J]. Journal of Applied Optics, 2006, 27(supp): 47-50.

Catalog

    Article views (2138) PDF downloads (890) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return