GE Jing-jing, LIN Zhao-rong, ZHU Da-kai. Design of mid-wave infrared continuous zoom system[J]. Journal of Applied Optics, 2013, 34(5): 728-732.
Citation: GE Jing-jing, LIN Zhao-rong, ZHU Da-kai. Design of mid-wave infrared continuous zoom system[J]. Journal of Applied Optics, 2013, 34(5): 728-732.

Design of mid-wave infrared continuous zoom system

More Information
  • Aiming at the cooled 320256 detector with staring focal plane array (FPA), an optical system of middle infrared continuous zoom system was designed for airborne optoelectronic detection and tracking apparatus. The system was composed of a zoom lens system, a secondary imaging system and two reflectors. In order to avoid the fabrication and testing error of aspheric surface, the whole system was made of nine spherical glasses. The design results indicate that the system achieves the continuous zoom of 37.5 mm~150 mm, with working length of 3.7 m~4.8 m, and F number of 4, which can obtain the cold shield efficiency of 100%. At the Nyquist frequency of 16 lp/mm, the MTF values of all focal length positions and field of view are more than 0l55, which are closing to the diffraction limit. The overall lens length is 280 mm and the weight is only 110 g. The optical system has the advantages of small volume, high image quality and simple structure.
  • [1]郁道银.工程光学[M].北京:机械工业出版社,2002.
    YU Dao-yin.Engineering optics[M].Beijing:China Machine Press,2002. (in Chinese)
    [2]陶纯堪.变焦距光学系统设计[M].北京:国防工业出版社,1988.
    TAO Chun-kan.Design of zoom optical system[M].Beijing:National Defence Industry Press,1988. (in Chinese)
    [3]YORAM A, ISAK B,REUVEN S. Topaz a novel design of a high-magnification athermalized 1:30 zoom in the MWIR[J]. SPIE, 2004, 5406:97-106.
    [4]骆守俊,何伍斌,李文虎,等.大面阵中波红外连续变焦光学系统设计[J].光学精密工程,2012,20(10):2117-2122.
    LUO Shou-jun, HE Wu-bai, LI Wen-hu, et al. Design of middle infrared continuous zoom optical system with a large FPA[J].Optics and Precision Engineering, 2012,20(10):2117-2122. (in Chinese with an English abstract)
    [5]许照东, 刘欣, 董涛. 机载高分辨率连续变焦红外热像仪设计 [J]. 红外与激光工程, 2007, 36(5): 619-621.
    XU Zhao-dong,LIU Xin,DONG Tao. Design of airborne high resolution and continuous magnification IR thermal imager[J]. Infrared and Laser Engineering,2007,36(5):619-621. (in Chinese with an English abstract)
    [6]陈吕吉,李萍. 光学补偿中波红外连续变焦光学系统设计 [J].红外技术,2010, 32(10): 562-566.
    CHEN Lü-ji,LI Ping.Optically compensated MWIR zoom system[J].Infrared Technology,2010,32(10):562-566. (in Chinese with an English abstract)
    [7]张良. 中波红外变焦距系统的光学设计 [J]. 应用光学,2006, 27(1): 32-35.
    ZHANG Liang. Optical design for middle infrared zoom system[J]. Journal of Applied Optics,2006,27(1):32-34. (in Chinese with an English abstract)
    [8]杨为锦,孙强. 中波红外连续变焦系统设计[J]. 中国光学与应用光学,2010,3(2):164-169.
    YANG Wei-jin, SUN Qiang. Design of middle infrared continuous zoom system[J]. Chinese Journal of Optics and Applied Optics,2010,3(2):164-169.(in Chinese with an English abstract)
  • Related Articles

    [1]CHANG Lingying, SONG Jingjing, JIN Mengzhu. Study on spectral transfer function based on dual AOTF acousto-optic crystal[J]. Journal of Applied Optics, 2019, 40(2): 202-209. DOI: 10.5768/JAO201940.0201004
    [2]Chang Lingying, Zheng Aiguo, Song Jingjing. Study on diffraction efficiency of acousto-optical crystal in AOTF imaging spectrometer[J]. Journal of Applied Optics, 2018, 39(3): 359-365. DOI: 10.5768/JAO201839.0302003
    [3]Wang Xiaofeng, Shi Yan, Zhuang Yi, Wang Shiyu. Optical design of zoom structured light imaging system[J]. Journal of Applied Optics, 2018, 39(1): 22-27. DOI: 10.5768/JAO201839.0101004
    [4]Zhang Yan, Wang Xiaobing, Geng Shunshan, Zhu Jiayi, Xu Aidong. MRTD in multispectral infrared imaging system based on AOTF[J]. Journal of Applied Optics, 2016, 37(6): 932-937. DOI: 10.5768/JAO201637.0606002
    [5]Li Yong-shuai, Wang Zhi-bin, Chen You-hua, Zhang Yu-han. Optical design of large FOV imaging system for AOTF imaging spectrometer[J]. Journal of Applied Optics, 2015, 36(1): 41-45. DOI: 10.5768/JAO201536.0101008
    [6]Cui En-kun, Zhang Bao, Hong Yong-feng. Design of initial structure of infrared zoom optical system with PW solution[J]. Journal of Applied Optics, 2014, 35(4): 586-591.
    [7]GAO Shu-li. Tunable range of acousto-optical tunable erbium-doped fiber ring laser[J]. Journal of Applied Optics, 2010, 31(5): 800-804.
    [8]LIU Qi-neng. Theoretical study on photonic crystal tunable filter with multiple channels[J]. Journal of Applied Optics, 2008, 29(4): 639-643.
    [9]HU Ji-xian. Design of long focal length large-aperture optical zoom system[J]. Journal of Applied Optics, 2007, 28(5): 569-572.
    [10]HE Zong-pin, ZHAO Wen-cai, WANG Peng, HAO Pei-ming. A Method of Solving the Initial Structure of a Three-thin-lens Null Corrector[J]. Journal of Applied Optics, 2004, 25(1): 21-23.

Catalog

    Article views (2417) PDF downloads (451) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return