YIN Wan-hong, LI Xu-dong, LI Gao-ping, LI Si-wei, LI Jie. Temperature measurement using bandpass infrared colorimetric filter[J]. Journal of Applied Optics, 2012, 33(6): 1097-1100.
Citation: YIN Wan-hong, LI Xu-dong, LI Gao-ping, LI Si-wei, LI Jie. Temperature measurement using bandpass infrared colorimetric filter[J]. Journal of Applied Optics, 2012, 33(6): 1097-1100.

Temperature measurement using bandpass infrared colorimetric filter

More Information
  • The bandpass colorimetric filter temperature measurement theory was presented, which could accurately measure the object at medium-low temperature, meanwhile, a series of experimental facility were built up based on the theory. The facilities used were calibrated accurately and the discrete data were fitted by using numerical function, a temperature-measurement experiment was done using extended blackbody in the range of 50℃~400℃. Experiment result implies that the facility can precisely obtain the true temperature of a measured objection without the presence of target launch rate. Therefore, it proves the validity of the theory and the feasibility of the temperature-measurement system matching the theory, which plays a key role in the accurate measurement of the medium-low temperature objects.
  • [1]戴景民.多光谱辐射测温理论与应用[M].北京:高等教育出版社,2002.
    DAI Jing-min. Theory and practice of multi spectral thermometry[M]. Beijing: Higher Education Press, 2002.(in Chinese)
    [2]王魁汉.温度测量实用技术[M].北京:机械工业出版社,2006.
    WANG  Kui-han. Wendu celiang shiyong jishu[M]. Beijing: Press of Mechanical Industry, 2006.(in Chinese)
    [3]KRZYSZTOF C, ZBIGNIEW  B, MAREK S. Comparison of temperature resolution of singleband, dualband, and  multiband infrared  systems[J]. Applied Optics,1999,38(13):2820-2823.
    [4]吴福田,张钦成.红外测温仪光学系统像质评价的一种方法[J].应用光学,1992,13(5):16-19.
    WU  Fu-tian, ZHANG Xin-cheng. An image quality evaluating method of optical system in IR thermometer [J]. Journal of Applied Optics, 1992,13(5):16-19.(in Chinese with an English abstract)
    [5]ZHU Liang-long, FAN Qi-song. Flight test of infrared radiation characteristic measurement on army using  dynamic  targets and environmen[J].Flight Test, 1990,34 (1 ):20-23.
    [6]YU Dao-pin, TAN Heng-ying. Engineering optics [M]. Beijing:China Machine Press, 1999.
    [7]LI Han-zhou, PAN Quan, ZHANG Hong-cai, et al. A study of algorithms of temperature measurement based on digital image processing[J]. China Electrical Engineering Transaction, 2003,23(6):195-199.
    [8]FEI S S, TECHNOLOGY  P, RESEARCH, et al. Neural network theory and the realization of  MATLAB7[M]. Beijing : Publishing House of Delectronics Industry, 2006.
    [9]EDWARD B M. Theory and engineering application of MATLAB[M]. Beijing: Publishing House of Electronics Industry, 2002.
    [10]白瑜,邢廷文,林妩媚,等.中波红外成像无热化光学系统设计[J].应用光学,2012,33(1):181-185.
    BAI Yu, XING Ting-wen, LIN Wu-mei, et  al. Athermalization of  middle infrared optical system [J]. Journal of Applied Optics, 2012,33(1):181-185. (in Chinese with an English abstract)
  • Related Articles

    [1]DU Cuicui, KONG Deren, XU Chundong. Acceleration test of substrate-packaged fiber Bragg grating sensor[J]. Journal of Applied Optics, 2022, 43(1): 152-159. DOI: 10.5768/JAO202243.0108001
    [2]LI Qiantao, XIONG Changxin, YANG Changcheng. Research on chemical strengthening technology for K9 optical glass[J]. Journal of Applied Optics, 2021, 42(1): 188-193. DOI: 10.5768/JAO202142.0105002
    [3]Gao Aihua, Wang Shaogang, Yan Lirong. Highprecision laser absorption rate measuring device[J]. Journal of Applied Optics, 2016, 37(2): 303-307. DOI: 10.5768/JAO201637.0207001
    [4]Liu hao, Pan feng, Wei Yao-wei, Ma ping, Zhang Zhe, Zhang Qing-hua, Wu Qian. Influence of defects in HfO2 film on absorptance and LIDT measurements[J]. Journal of Applied Optics, 2015, 36(2): 314-320. DOI: 10.5768/JAO201536.0207004
    [5]Zhang Zhi-hao, Song Qiang, Yao Qiang. Influence of flame atomic absorption on measurement of K using laser-induced breakdown spectroscopy[J]. Journal of Applied Optics, 2014, 35(5): 917-921.
    [6]LIU Hao, MA Ping. Uncertainty analysis of laser calorimetry[J]. Journal of Applied Optics, 2011, 32(5): 942-948.
    [7]YU Shuai, LI Gao-ping, SANG Peng, WU Yao. Bulk absorption laser calorimeter operating in non-standard environment[J]. Journal of Applied Optics, 2009, 30(4): 646-649.
    [8]CHEN Jun, ZHANG Qun-li, YAO Jian-hua, FU Ji-bin. Study on laser absorptivity of metal material[J]. Journal of Applied Optics, 2008, 29(5): 793-798.
    [9]PANG Yun-xia, HANG Ling-xia, CHEN Zhi-li, MA Bao-ji. Investigation on subsurface damage detection of K9 optics[J]. Journal of Applied Optics, 2007, 28(6): 773-777.
    [10]YU Shuai, LI Gao-ping, YANG Zhao-jin, WU Yao, SANG Peng, GUO Yu. Energy loss compensation of bulk absorption laser energy meter[J]. Journal of Applied Optics, 2007, 28(5): 659-662.

Catalog

    Article views (2618) PDF downloads (426) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return