TAO Wei, WU Guo-jun, GUAN Yun-tian. Chromatic thermometry used in ceramic sintering process[J]. Journal of Applied Optics, 2012, 33(5): 940-943.
Citation: TAO Wei, WU Guo-jun, GUAN Yun-tian. Chromatic thermometry used in ceramic sintering process[J]. Journal of Applied Optics, 2012, 33(5): 940-943.

Chromatic thermometry used in ceramic sintering process

More Information
  • The method of chromatic thermometry was introduced into the on-line thermometry of ceramic sintering. The thermometry system was designed according to Planck law. The calculation methods of key parameters, such as wavelength, emissivity, rate of conversion, were presented. The relation between wavelength and energy/sensitivity was comprehensively analyzed. The prototype was set up and tested according to the characteristics of ceramic sintering process, and the results indicated the metering error was less than 10 K during 1 300 K~2 000 K.
  • [1]张金敏. 基于数据融合的陶瓷窑炉温度记录仪的研究[J]. 自动化与仪器仪表, 2010(4):116-118.
    ZHANG Jin-min. Development of ceramic kiln temperature recorde based on data fusion technology[J].  Automation & Instrumentation,2010(4):116-118.(in Chinese with an English abstract)
    [2]陈昌虎,李蔓华,李晓高. 窑炉用热电阻、热电偶智能温度测量板的设计[J]. 中国陶瓷, 2007,43(1):55-57.
    CHEN Chang-hu,LI Man-hua,LI Xiao-gao. Design of  brainpower temperature measurement board used for kilns[J]. China Ceramics, 2007,43(1):55-57. (in Chinese with an English abstract)
    [3]占春连, 李燕梅, 刘建平,等. 热辐射体真实温度的测试研究[J]. 应用光学, 2002,23(6):39-41,44.
    ZHAN Chun-lian, LI Yan-mei, LIU Jian-ping, et al. Research onmeasurement of real temperature  of  thermal rad  iator[J]. Journal of Applied Optics, 2002,23(6):39-41,44. (in Chinese with an English abstract)
    [4]BHATTACHARJEE S. Approximate two-color emission pyrometry [J]. J of Heat TransferTrans of the ASME, 2000,122(1):15-20.
    [5]李杰,王志敏,吴凤泉,等. 工业用比色测温仪的校准研究[J]. 仪器仪表标准化与计量, 2009(2):21-23.
    LI Jie, WANG Zhi-min, WU Feng-quan. Research on calibration of comparing color thermometer in industry[J]. Instrument Standardization & Metrology, 2009(2):21-23.(in Chinese with an English abstract)
    [6]赵英杰,李维军,李萍. 修正的比色测温法在水泥窑图像温度检测系统中的应用研究[J]. 检测与计量, 2009(2):76-78.
    ZHAO Ying- jie, LI Wei- jun, LI Ping. The application research of the modified method of color comparason temperature measurement in the dynamic image temperature measurement system[J]. Cement Technology, 2009(2):76-78. (in Chinese with an English abstract)
    [7]周洁,高金睿,王志强,等. 微波烧结法制备TCP/TTCP复合生物陶瓷材料的研究[J]. 硅酸盐通报. 2009,28(3):495-499.
    ZHOU Jie, GAO Jin-rui, WANG Zhi-qiang, et al. Study on the TCP / TTCP calcium phosphate composite bio-ceramics prepared by microwave sintering method[J]. Bulletin of the Chinese Ceramic  Society, 2009,28(3):495-499. (in Chinese with an English abstract)
    [8]于沿波,王光平,王天赦. 隧道窑烧成带高温参数测量[J]. 耐火材料,1999,33(6):349-350;357.
    YU Yan-bo, WANG Guang-ping, WANG Tian-she. Measurement of high-temperature parameters in the firing section of the tunnel kiln[J]. Naihuo Cailiao, 1999,33(6):349-350;357. (in Chinese with an English abstract)
    [9]艾云龙,刘书红,刘长虹,等. 陶瓷材料的微波烧结及研究进展[J]. 热处理技术与装备, 2008,29(3):1- 4.
    AI Yun-long, LIU Shu-hong, LIU Chang-hong, et al. Development and microwave sintering of ceramic materials[J]. Rechuli  Jishu Yu Zhuangbei, 2008,29(3):1-4. (in Chinese with an English abstract)
    [10]郑维民, 张晓娟. 用红外测温仪观察二极管板流引起的阴极降温现象[J]. 应用光学, 2009,30(1):134-138.
    ZHENG Wei-min, ZHANG Xiao-juan. Observation of cathode temperature-drop phenomenon caused by diode board-current with IR thermometer[J]. Journal of Applied Optics, 2009,30(1):134-138. (in Chinese with an English abstract)
  • Related Articles

    [1]FU Chao, WANG Shiyu, LI Bingbin, LI Lequn. Influence of resonant cavity state on beam pointing stability of high-power Nd:YAG pulsed solid-state laser[J]. Journal of Applied Optics, 2024, 45(6): 1298-1306. DOI: 10.5768/JAO202445.0607003
    [2]YAO Linhai, LU Peiguo, YANG Yong'an, LONG Jingyu, YANG Xiulin, BU Yinghua. High precision measurement method of laser beam pointing stability[J]. Journal of Applied Optics, 2022, 43(2): 339-344. DOI: 10.5768/JAO202243.0207001
    [3]LI Huifeng, LYU Xinguang. Study on color stability under different light sources based on color difference analysis[J]. Journal of Applied Optics, 2020, 41(6): 1247-1254. DOI: 10.5768/JAO202041.0603005
    [4]Ma Gangfei, Yao Wenming, Ju Qiaojun, Tan Huiming, Yang Jianming, Jiang Yu, Gao Jing. 561 nm yellow laser with high stability and low noise[J]. Journal of Applied Optics, 2017, 38(3): 499-505. DOI: 10.5768/JAO201738.0307002
    [5]Ma Aiqiu, Yang Pengli, Bai Zhao, Zhang Ming, Fu Xiaoqing, Zeng Bo, Liu Weiguang. Assembling and adjusting technique for#br# improving optical axis stabilization of zoom TV[J]. Journal of Applied Optics, 2016, 37(4): 602-606. DOI: 10.5768/JAO201637.0405002
    [6]XU Jiang-tao, CHENG Yao-jin, LIU Feng, LI Min, LIU Bei-bei. Stability of transmission GaAs cathode photoemission of3rd generation image intensifier[J]. Journal of Applied Optics, 2013, 34(3): 489-493.
    [7]YE Lu. Temperature stability analysis of static angle calibration devices[J]. Journal of Applied Optics, 2012, 33(2): 333-336.
    [8]ZHANG Qiang, WANG Yue-feng, ZHU Xiao-peng, HOU Jun-yan, WEI Ming. Stability of LD dual-end pumped U-folded resonator Nd∶YVO4 laser[J]. Journal of Applied Optics, 2010, 31(6): 1027-1031.
    [9]FENG Liu, LIU Hui, CHENG Hong-chang, SHI Feng, SHI Peng-fei, REN Bing, ZHANG Lian-dong. Influence of different Cs-to-O current ratios on sensitivity and stability of activating GaAs photocathodes[J]. Journal of Applied Optics, 2009, 30(4): 654-658.
    [10]ZHAO De-shuang, LIU Yong-zhi, HUANG Xiu-jiang, ZHANG Chang-ming. Stability of Passively Modelocked Femtosecond Fiber Laser[J]. Journal of Applied Optics, 2005, 26(4): 26-29.

Catalog

    Article views (2786) PDF downloads (441) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return