LI Qian, LIU Xue-song, GUAN Yun-tian. Distortion measurement of grating head-up display[J]. Journal of Applied Optics, 2012, 33(5): 915-919.
Citation: LI Qian, LIU Xue-song, GUAN Yun-tian. Distortion measurement of grating head-up display[J]. Journal of Applied Optics, 2012, 33(5): 915-919.

Distortion measurement of grating head-up display

More Information
  • The distortion of grating head-up display seriously affects the observation, measurement, positioning and analysis of object. Therefore its distortion quantitative measurement must be finished during the process of setting and assembling. Combining with the work principle and distortion causes of grating head-up display and utilizing the photoelectric measurement technology, its distortion quantitative measurement was further studied. Firstly, the distortion measurement system was set up to measure the distortion of grating head-up display caused by different reasons, and its CCD detector was calibrated. Secondly, the calibrated CCD detector was used to measure the distortion of grating head-up display, and the uncertainty of distortion measurement was analyzed. Utilizing this distortion measurement system, the experimental results show that the uncertainty of the relative distortion measurement of grating head-up display is 0.5%.
  • [1]郑为民.光栅平视显示器的研究[J].电光与控制,1997(1):29-34.
    ZHENG Wei-min. Research on grating head-up display[J]. Electronics Optics& Control,1997(1):29-34.(in Chinese with an English abstract)
    [2]张华达.大视场短焦距CCD成像系统畸变校正研究[J].红外月刊,2004(1):1-6.
    ZHANG Hua-Da. Research on distortion calibration of short-focal-length CCD imaging system[J]. Infrared,2004(1):1-6. (in Chinese with an English abstract)
    [3]金石娇,韩兆福,葛银茂,等.某型平视显示器非线性失真的校正[J].计量与测试技术,2006,33(7):16-17.
    JIN Shi-jiao, HAN Zhao-fu, GE Yin-mao. Correction of  non-liner distortion in head-up display[J]. Metrology& Measurement Technique,2006,33(7):16-17. (in Chinese with an English abstract)
    [4]周海宪,程云芳.全息光学:设计、制造与应用[M].北京:化学工业出版社,2006.
    ZHOU Hai-xian, CHENG Yun-fang. Holographic optics: design, manufacture and application[M]. Bei Jing: Chemical Industry Press, 2006. (in Chinese )
    [5]郭羽,杨红,杨金照,等.CCD摄像系统的畸变测量[J].应用光学,2008,29(2):279-282.
    GUO Yu, YANG Hong, YANG Zhao-jin. Distortion measurement of lens in CCD camera system[J]. Journal of Applied Optics, 2008, 29(2):279-282. (in Chinese with an English abstract)
    [6]张全法,何金田.提高广角成像系统几何畸变数字校正精度的方法[J].光学技术,2001,27(3):242-246.
    ZHANG Quan-fa, HE Jin-tian. Improving the precision of digital distortion correction of wide-angle imaging system[J]. Optical Technique, 2001,27(3):242-246. (in Chinese with an English abstract)
    [7]沙定国.误差分析与测量不确定度评定[M].北京:中国计量出版社,2003:124-151.
    SHA Ding-Guo. Error analysis and evaluation of measurement uncertainty[M]. Beijing: China Metrology press, 2003:124-151. (in Chinese )
    [8]刘力双,孙双花.一种基于网格的图像测量系统高精度标定方法[J].工具技术,2008,42(1):140-144.
    LIU Li-shuang, SUN Shuang-hua. A high-precision calibration method for imaging measurement system based on mesh grids[J]. Tool Engineering, 2008,42(1):140-144. (in Chinese with an English abstract)
    [9]魏新国,张广君,江洁.星敏感器中星图图像的星体细分定位方法研究[J].北京航空航天大学学报,2003,29(9):812-815.
    WEI Xin-guo, ZHANG Guang-jun, JIANG Jie. Subdivided locating method of star image for star sensor[J]. Journal of Beijing University of Aeronautics and Astronautics, 2003,29(9):812-815. (in Chinese with an English abstract)
    [10]谢伦治,卞洪林,王振华.面阵探测器的像点亚像素定位研究[J].光学与光电技术,2003,1(2):51-56.
    XIE Lun-zhi, BIAN Hong-lin, WANG Zhen-hua. Study of the subpixel interpolation of image spots with matrix detectors[J]. Optics&Optoelectronic Technology, 2003,1(2):51-56. (in Chinese with an English abstract)
  • Related Articles

    [1]ZHU Guangyi, JIN Shangzhong, WU Lei, XUE Yuanyuan, MO Yunlong, YOU Yue, ZHANG Yunlong, YU Bing, YANG Hongru, DONG Zaitian, LU Fei. Peak power measurement device of terawatt femtosecond pulsed laser and measurement uncertainty analysis[J]. Journal of Applied Optics, 2024, 45(2): 398-404. DOI: 10.5768/JAO202445.0203001
    [2]Xiao Shaorong, Huang Biao, Huang Xing, Zhou Weiwei. Effect of bandpass filter on uncertainty of visibility measurement[J]. Journal of Applied Optics, 2016, 37(5): 712-718. DOI: 10.5768/JAO201637.0503001
    [3]Li Zhi-feng, Zhao Deng-feng, Ma Guo-lu, Zeng Guo-ying, Lu Zhan. Bending and torsion measuring system of rotary parts and it’s uncertainty analysis[J]. Journal of Applied Optics, 2015, 36(5): 778-783. DOI: 10.5768/JAO201536.0503003
    [4]WANG Xu, WANG Zhong-yu, ZHAO Wei-qian, QIU Li-rong. Uncertainty evaluation in laser differential confocal radius-of-curvature measurement[J]. Journal of Applied Optics, 2014, 35(1): 155-158.
    [5]LIU Hao, MA Ping. Uncertainty analysis of laser calorimetry[J]. Journal of Applied Optics, 2011, 32(5): 942-948.
    [6]CHEN Jie-chun, ZHAO Li-ping, GUO ming. Uncertainty evaluation of corner detection[J]. Journal of Applied Optics, 2011, 32(3): 477-481.
    [7]ZHAO Gao-chang, WU Feng-bo, ZHOU Bin, YANG Zhong-min, QIAO Bao-ming. Simplified method to calibrate cameras based on DLT model[J]. Journal of Applied Optics, 2009, 30(4): 585-589.
    [8]WANG Hong-hong, CHEN Fang-bin, JIANG Tao, LI Guang-liang. Adaptive SMC for nonlinear optoelectronic servo ystem with uncertainty[J]. Journal of Applied Optics, 2009, 30(2): 242-245.
    [9]SHI Ji-fang, SONG Yi-bing, JI Xiao. Evaluation of uncertainty measurement for laser energy meter[J]. Journal of Applied Optics, 2006, 27(supp): 47-50.
    [10]YANG Ye-ping, YANG Zhao-jin, HOU Min. The Uncertainty Analysis of the Calibration Measurement of Main Performances for Laser Rangefinders[J]. Journal of Applied Optics, 2005, 26(4): 56-57.

Catalog

    Article views (3159) PDF downloads (491) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return