HAN Zhansuo, CAO Feng, WANG Jian’gang, LUO Beibei, QIN Yan, LIU Fang. Testing method about infrared radiation intensity of explosive used in vacuum environment[J]. Journal of Applied Optics, 2020, 41(6): 1230-1235. DOI: 10.5768/JAO202041.0603002
Citation: HAN Zhansuo, CAO Feng, WANG Jian’gang, LUO Beibei, QIN Yan, LIU Fang. Testing method about infrared radiation intensity of explosive used in vacuum environment[J]. Journal of Applied Optics, 2020, 41(6): 1230-1235. DOI: 10.5768/JAO202041.0603002

Testing method about infrared radiation intensity of explosive used in vacuum environment

More Information
  • Received Date: April 14, 2020
  • Revised Date: August 16, 2020
  • Available Online: September 27, 2020
  • For explosives in atmospheric environment, the radiation intensity of the test method is relatively mature. With the rapid development of high altitude or outside atmosphere explosives development technology, for such explosive transient testing requirements of infrared radiation intensity become more and more urgent. Since the outer space environment was a kind of low temperature near the vacuum environment, and the field measurement was not available, it was creatively put forward the simulation of vacuum environment in the laboratory to test the infrared radiation intensity of explosive, and a dedicated vacuum environment and testing methods were further established. The 4 sets of specific components of the fire explosives were measured using the special test equipment, and the measurement results were analyzed. In view of the existing problems, the future direction of improvement was expounded.
  • [1]
    吴宝宁, 王乐, 曹锋, 等. 火炸药瞬态红外辐射强度测试研究[J]. 应用光学,2016,37(Sup):98-101.

    WU Baoning, WANG Le, CAO Feng, et al. Measurement of transient infrared radiation intensity for explosive[J]. Journal of Applied Optics,2016,37(Sup):98-101.
    [2]
    梁培. 标准红外目标模拟器辐照度验证[J]. 计量技术,2001(3):3-5. doi: 10.3969/j.issn.1000-0771.2001.03.001

    LIANG Pei. Standard infrared target simulator irradiance verification[J]. Measurement Technique,2001(3):3-5. doi: 10.3969/j.issn.1000-0771.2001.03.001
    [3]
    张建奇, 方小平. 红外物理[M]. 西安: 西安电子科技大学出版社, 2004.

    ZHANG Jianqi, FANG Xiaoping. Infrared physics[M]. Xi’an: Xidian University Press, 2004.
    [4]
    WILLIAM R M. Introduction to radiometry and photometry[M]. UK: Artech House, 2014.
    [5]
    HENGSTBERGER F. Absolute radiometry electrically calibrated thermal detectors of optical radiation[M]. US: Academic Press, 1989.
    [6]
    WILLIAM L. Introduction to radiometry[M]. US: SPIE Press, 1998.
    [7]
    MICHAEL B. Applied photometry radiometry and measurements of optical losses[M]. US: Springer Science and Business Media, 2012.
    [8]
    ANTONI R. Infrared detector[M]. US: CRC Press, 2011.
    [9]
    MICHAEL C D. Electro-optical systems and testing[M]. US: SPIE Press, 1993.
    [10]
    PALMER J M. The art of radiometry[M]. US: SPIE Press, 2010.
    [11]
    杨扬. 红外目标模拟器辐照度模拟与测量方法研究[D]. 哈尔滨: 哈尔滨工业大学, 2010.

    YANG Yang. Research on irradiance simulation and measurement of infrared target simulator[D]. Harbin: Harbin Institute of Technology, 2010.
    [12]
    张国宾. 红外寻的导引头检测装置[D]. 长春: 长春理工大学, 2011.

    ZHANG Guobin. Detecting device of infrared homing seeker[D]. Changchun: Changchun University of Science and Technology, 2011.
    [13]
    胡铁力, 申越, 郭羽, 等. 低噪声红外辐射计设计[J]. 应用光学,2013,34(4):663-666.

    HU Tieli, SHEN Yue, GUO Yu, et al. Low noise infrared radiometer[J]. Journal of Applied Optics,2013,34(4):663-666.
    [14]
    王中宇, 夏新涛, 朱坚民. 测量不确定度的非统计理论[M]. 北京: 国防工业出版社, 2000.

    WANG Zhongyu, XIA Xintao, ZHU Jianmin. Nonstatistical theory of measurement uncertainty[M]. Beijing: National Defence Industry Press, 2000.
    [15]
    JACOBS P A. Thermal infrared characterization of ground targets and backgrounds[M]. US: SPIE Press, 2006.

Catalog

    Article views (1369) PDF downloads (27) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return