SHA Tongtong, HU Xiaodong, ZHAO Jintao, ZOU Jing. Measurement method research for Micro-CT system based on combined calibrator[J]. Journal of Applied Optics, 2020, 41(4): 810-815. DOI: 10.5768/JAO202041.0409802
Citation: SHA Tongtong, HU Xiaodong, ZHAO Jintao, ZOU Jing. Measurement method research for Micro-CT system based on combined calibrator[J]. Journal of Applied Optics, 2020, 41(4): 810-815. DOI: 10.5768/JAO202041.0409802

Measurement method research for Micro-CT system based on combined calibrator

More Information
  • Received Date: September 28, 2019
  • Revised Date: October 22, 2019
  • Available Online: June 14, 2020
  • In order to ensure the measurement accuracy of the Micro-Computed Tomography (Micro-CT) system, a combined measurement mode of the calibrator and the sample was adapted to design the combined calibrator which can be used for the combined measurement, and a method to correct the proportional error and the threshold error in the measurement process of the Micro-CT system was proposed. Without changing the scanning parameters of the Micro-CT system, the samples of polytetrafluoroethylene, a light material commonly used in aerospace, were measured independently and compared with the measurements based on the combined calibrator. The results show that compared with the sample independent measurement method, the proposed method can effectively reduce the measurement error of 1 μm~4 μm and has better robustness.
  • [1]
    KIEKENS K, WELKENHUYZEN F, TAN Y, et al. A test object with parallel grooves for calibration and accuracy assessment of industrial computed tomography(CT) metrology[J]. Measurement Science and Technology,2011,22(11):115502. doi: 10.1088/0957-0233/22/11/115502
    [2]
    ZHAO J T, HU X D, ZOU J, et al. Method for correction of rotation errors in micro-CT system[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2016,816:149-159.
    [3]
    JIMÉNEZ R, ONTIVEROS S, CARMIGNATO S, et al. Correction strategies for the use of a conventional micro-CT cone beam machine for metrology applications[J]. Procedia CIRP,2012,2:34-37. doi: 10.1016/j.procir.2012.05.035
    [4]
    KRUTH J P, BARTSCHER M, CARMIGNATO S, et al. Computed tomography for dimensional metrology[J]. CIRP Annals,2011,60(2):821-842. doi: 10.1016/j.cirp.2011.05.006
    [5]
    BARTSCHER M, HILPERT U, GOEBBELS J, et al. Enhancement and proof of accuracy of industrial computed tomography(CT) measurements[J]. CIRP Annals,2007,56(1):495-498. doi: 10.1016/j.cirp.2007.05.118
    [6]
    HSEIH J. Computed tomography - principles, design, artifacts and recent advances[M]. [S.l.]: SPIE The International Society for Optical Engineering, 2003.
    [7]
    BARTSCHER M, SATO O, HÄRTIG F, et al. Current state of standardization in the field of dimensional computed tomography[J]. Measurement Science and Technology,2014,25(6):064013. doi: 10.1088/0957-0233/25/6/064013
    [8]
    MÜLLER P, HILLER J, DAI Y, et al. Quantitative analysis of scaling error compensation methods in dimensional X-ray computed tomography[J]. CIRP Journal of Manufacturing Science and Technology,2015,10:68-76. doi: 10.1016/j.cirpj.2015.04.004
    [9]
    STOLFI A, DE CHIFFRE L. 3D artefact for concurrent scale calibration in computed tomography[J]. CIRP Annals,2016,65(1):499-502. doi: 10.1016/j.cirp.2016.04.069
    [10]
    陈思, 陈浩, 李敬, 等. 一种工业CT测量精度评估方法[C]//全国射线数字成像与CT新技术研讨会论文集. 绵阳: 中国体视学学会, 2012: 193-201.

    CHEN Si, CHEN Hao, LI Jing, et al. An evaluation method for measurement accuracy of industrial CT[C]//Proceedings of the National Conference on New Technologies in Radiographic Digital Imaging and CT. Mianyang: Chinese Society for Stereology, 2012: 193-201.
    [11]
    陈思文. 测量型显微CT系统的定值方法[D]. 天津: 天津大学, 2016.

    CHEN Siwen. A method to calibrate micro-CT metrology system[D]. Tianjin: Tianjin University, 2016.
    [12]
    张建隆, 潘鑫, 贺磊, 等. 全视角高精度三维测量仪光学系统误差分析研究[J]. 应用光学,2018,39(3):392-399.

    ZHANG Jianlong, PAN Xin, HE Lei, et al. Error analysis of optical system for full-view and high-precision three-dimensional measuring instrument[J]. Journal of Applied Optics,2018,39(3):392-399.
    [13]
    CHRISTOPH R, NEUMANN H J. X-ray tomography in industrial metrology: precise, economical and universal[J]. Verlag Moderne Industrie,2012, 19 (2): 213-217.
    [14]
    邱磊, 钱斌, 伏燕军, 等. 基于正弦和三角波条纹投影的三维测量方法[J]. 应用光学,2018,39(4):522-527.

    QIU Lei, QIAN Bin, FU Yanjun, et al. Three-dimensional shape measurement method based on sinusoidal and triangular fringe projection[J]. Journal of Applied Optics,2018,39(4):522-527.
    [15]
    国家质量监督检验检疫总局. GB/T 34874.3-2017 产品几何技术规范(GPS): X射线三维尺寸测量机——第3部分: 验收检测和复检检测[S]. 北京: 中国标准出版社, 2017: 14-15.

    General Administration of Quality Supervision, Inspection and Quarantine. GB/T 34874.3-2017 Geometrical product specifications (GPS): X-ray three-dimensional size measuring machines—Part 3: Acceptance inspection and reverification tests[S]. Beijing: China Standard Press, 2017: 14-15.
  • Related Articles

    [1]CHEN Peng, LIU Huiting, ZHANG Lei, WANG Keyi, CAI Bolin. High-precision occlusion-resistant quad-vision camera 3D reconstruction system[J]. Journal of Applied Optics, 2024, 45(2): 307-313. DOI: 10.5768/JAO202445.0201005
    [2]HU Xiaoli, TANG Minggang, CAI Wenze, ZHANG Yulun, ZHANG Siqi, ZHANG Sanxi. Influence of optical axis pointing error on optical pose measurement accuracy[J]. Journal of Applied Optics, 2023, 44(2): 365-370. DOI: 10.5768/JAO202344.0203001
    [3]SONG Lizheng, LIN Dongyun, PENG Xiafu, LIU Tengfei. Patch-match binocular 3D reconstruction based on deep learning[J]. Journal of Applied Optics, 2022, 43(3): 436-443. DOI: 10.5768/JAO202243.0302003
    [4]XI Shaojie, ZHANG Zonghua, GAO Nan, MENG Zhaozong. Calibration method of 3D scanner tilt angle based on IMU[J]. Journal of Applied Optics, 2022, 43(2): 291-297. DOI: 10.5768/JAO202243.0203003
    [5]YU Zihao, LIU Jin, YANG Haima, LI Meiying, XU Wei, XU Bin. Research on 3D measurement and reconstruction of high-precision profile of multi-frequency grating object[J]. Journal of Applied Optics, 2020, 41(3): 580-585. DOI: 10.5768/JAO202041.0303006
    [6]Hong Han-yu, Luo Xiao, Song Jie, Shi Yu. Efficient generation for 3D printing model based on image self-calibration[J]. Journal of Applied Optics, 2016, 37(1): 69-73. DOI: 10.5768/JAO201637.0102003
    [7]Zhu Tong-jing, Zhou Ping, Liu Xin-ran, Yuan Jun-jie. Crucial algorithms for structural light 3D measurement system calibration[J]. Journal of Applied Optics, 2014, 35(5): 848-852.
    [8]FENG Xiu, CHEN Xu, XU Nan, CHEN Fan-xiu, XIE Xin, YANG Lian-xiang. Measurement accuracy of out-of-plane displacement forbinocular vision DIC system[J]. Journal of Applied Optics, 2013, 34(3): 457-462.
    [9]BAO Xue-zhi, GAO Wei, JIA Yang-yu, LV Hong-peng. Influence of background scattering on measurement accuracy of laser radar cross section[J]. Journal of Applied Optics, 2008, 29(4): 590-594.
    [10]Xu Dai-sheng, Hu Yi-hua, hu Rong, Wang Jian-yu. An Improved Measurement Technique for Atmospheric Attenuation of Laser Transmittance[J]. Journal of Applied Optics, 2005, 26(5): 7-009.
  • Cited by

    Periodical cited type(1)

    1. 刘宝怡,张强,蒋世磊,孙国斌,杨国锋. 基于薄膜损伤阈值测试的聚焦光学系统设计. 光学与光电技术. 2025(01): 9-14 .

    Other cited types(1)

Catalog

    Article views (1507) PDF downloads (36) Cited by(2)

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return