干涉法标定单轴晶片的光轴方向

Calibration for optical axe direction of uniaxial crystal by interferometric method

  • 摘要: 量子通信实验中的光子纠缠源主要通过激光泵浦非线性晶体而产生。这类实验需要将晶体的光轴调在竖直平面内,一般采用偏振片来确定晶体光轴的方向,但仅通过消光现象只能确定晶体的2个本振方向,无法确定哪个方向是光轴方向。分析激光在通过偏振片与单轴晶体后,在观察屏上干涉条纹的走向与晶体光轴方向的关系,给出标定单轴晶体光轴方向的实验方法与实验结果。实验结果表明:光轴方向与干涉条纹的走向垂直,可以通过观察干涉条纹的走向来确定光轴的具体方向。

     

    Abstract: The entangled photon pair in quantum communication experiments is produced by laser pumping nonlinear crystal. In the experiments, it is necessary to adjust the optical axe of uniaxial crystal to the vertical plane. Usually, the optical axe direction is determined by polarizer, but this method can only give the two engine directions of the crystal. The relation between the direction of the optical axe and the trend of the interference fringes was analyzed. The experimental method and results for calibrating the optical axe direction of uniaxial crystal are offered. The experiment results show that the optical axe direction is perpendicular to the trend of interference fringes.

     

/